User's Manual
The switch “Termination” must be set depending on the the number of cables plugged in:
1 cable = “ON”, 2 cables = “OFF”. If you use only two devices (point-to-point connection), the termination
must always remain switched on.
Wrong termination settings are, depending on the cable length, not always immediately noticeable and
the system appears to function properly. But reliability and immunity to noise is significantly decreased,
because either signals reflections occur with missing termination or transmitters get overloaded by too
many terminations.
If you're using the system in the same setup all time, you may use scotch tape to fix the push button (or
remove the push button cap) in order to prevent unwanted operation.
NOTE: Redundant connections (the connection of two units with two cables over A and B at the same time) are
not
supported! This would lead to signal loops causing undefined current flow.
6.2. Cat5 Connection 2 (ADX-64B-PRO only)
Connection 2 for Cat5 cable (ADAT signals 5-8 and MIDI2 data)
8
A
B
Termination
1 (A/ B)
2 (A+B)
8
7
6
5
Power
ADAT Clock
Cat5 Connection 2