15
STF-R/C/D/IP Hardware Manual
920-0141 Rev. A
6/5/2018
2.4.2 CANopen address and baud rate settings(-C model)
Set drive’s CANopen address by rotary switch S1
Set drive’s CANopen baud rate by rotary switch S2
Each node on a CANopen network must have a unique Node ID. Valid ranges for the Node
ID are 0x01 through 0x7F (1~127). Node ID 0x00 is reserved in accordance with CiA301. The Node ID is selected using rotary
switches and software; one sixteen position switch set the lower four bits (0~F) of node ID, while upper three bits of node ID are
configured by
STF Configurator
software. Each time when Node ID is changed, a power cycle is required before the
new Node ID is valid.
Please refer to the CANopen manual for more information.
CANopen Baud Rate
There are 8 types of baud rate supported by CANopen communication on STF drive. It is set via S2 switch on the drive
S2 position
Baud Rate (bps)
0
1M
1
800K
2
500K
3
250K
4
125K
5
50K
6
20K
7
12.5K
8-9
Reserved
S1
S2
CANopen
Baud Rate
CANopen
Address