13
ST5/10-S Hardware manual
920-0027 Rev. A1
6/1/09
Connecting to PLC with Sinking (NPN) Outputs
(Most PLC’s use 24 volt logic)
Using Mechanical Switches at 24 Volts
Drive
+12-24V
DIR+
DIR
DIR-
STEP+
STEP
STEP-
PLC
with
Sinking
Outputs
R
R
Drive
+
DIR+
DIR-
STEP+
-
STEP-
+24VDC
Power
Supply
2200
2200
direction switch
run/stop switch
(closed=run)