Operating Conditions
For optimum carbon filter performance, observe the following:
Maintain a minimum of 25 psi during backwash cycle.
Water pressure should not exceed 120 psi across carbon tank.
Water temperature should not exceed 110 °F.
CAUTION: Hydrocarbons such as kerosene, benzene, gasoline, etc., may damage products that
contain o-rings or plastic components. Exposure to such hydrocarbons may cause the products to leak. Do
not use the product(s) contained in this document on water supplies that contain hydrocarbons such as
kerosene, benzene, gasoline, etc.
Operating Do’s and Don’ts
DO:
Monitor system and keep a daily log.
Maintain proper water pressure for backwashing.
DON’T:
Permit oils or fats in feed water.
Shut down system for extended periods.
Exceed operating pressures or temperatures.
Backwash filter with insufficient water flow.