Installation and Service Manual – Metered Carbon Filter
Page 19
Copyright © 2012 Applied Membranes, Inc. All Rights Reserved.
Diagnostics
For all steps below: Press the NEXT button to proceed to the next step. Press REGEN to return to previous step or exit.
STEP 1D
Press
▼
or
▲
simultaneously for three seconds. If screen in step 2D does not appear in 5
seconds the lock on the valve is activated. To unlock press
▼
, NEXT,
▲
, and SET
CLOCK in sequence, then press NEXT and
▼
simultaneously for 3 seconds.
STEP 2D
Days, since last regeneration: This display shows the days since the last regeneration
occurred.
STEP 3D
Gallons, since last regeneration: This display shows the number of gallons that have been
treated since the last regeneration.
STEP 4D
Gallons used each day for last 7 days Pressing the
▲
Button will show day 1 (which
would be yesterday) and flashes the gallons used. Pressing the
▲
button again will show
day 2 (the day before yesterday) and the gallons used. Keep
pressing the
▲
button to show the gallons for days 3, 4, 5 and 6.
The
▼
button can be pressed to move backwards in the day series.
STEP 5D
Gallons, 63 day usage history: This display shows day 1 (for
yesterday) and flashes the number of gallons treated yesterday.
Pressing the
▲
button will show day 2 (which would be the day
before yesterday) and flashes the number of gallons treated on that
day. Continue to press the
▲
button to show the maximum number of
gallons treated for the last 63 days. This display will show dashes if a water meter is not
installed.
STEP 6D
Flow rate, current: Turn the water on at one or more taps in the building. The flow rate in
gallons per minute will be displayed. If flow stops the value will fall to zero in a few
seconds.
STEP 7D
Flow rate, maximum last seven days: The maximum flow rate in gallons per minute that
occurred in the last seven days will be displayed.
STEP 8D
Gallons, total used since last reset: The total number of gallons used since last reset will
be displayed.
STEP 9D
Days, total number since last reset: The total number of days the control valve has been
in service since last reset will be displayed.
STEP 10D
Regenerations, total number since last reset: The total number of regenerations that have
occurred since last reset will be displayed.
When desired, all information in Diagnostics may be reset to zero. To reset to zero,
press NEXT and
▼
buttons simultaneously to go to the Service screen, and release.
Press
▼
and
▲
simultaneously to reset diagnostic values to zero. Screen will
return to user display.