AA System Operation Manual
Page 10 of 27
© 2007
INITIAL SYSTEM START-UP
SYSTEM FLUSH: Direct permeate discharge to drain for first 30 minutes of operation.
1.
Connect the system to the appropriate electrical outlet, 110vac or 220vac 1 phase. The
solenoid will open as soon the power is applied and the unit will come on if the feed
pressure is high enough. NOTE: Follow all NEC and local electrical codes.
2.
After water is flowing from the concentrate line, adjust the control valve to obtain 150
PSI on the system pressure gauge.
3.
Allow the unit to run for 30 minutes.
4.
After the flush time is over, turn the unit off by disconnecting the power.
5.
Redirect the permeate to the desired location.
6.
Turn the power back on. After the pump starts, adjust the control valve to the desired
pressure (not to exceed 150 psi). The recycle valve may now be adjusted and the
control and recycle valves used to set the system pressure and flows.
CAUTION: To prevent concentrate from precipitating and causing irreversible fouling of
the R.O. membrane, do not operate the system with the control valve
completely closed. Do not exceed recommended maximum recovery.