background image

Model 5112 Operation Manual

Applied Instruments Inc

Table of Contents

 1 INTRODUCTION..........................................................................................................3

 1.1 Symbols Used...........................................................................................................3
 1.2 Safety Instructions....................................................................................................3

 2  OPERATING INSTRUCTIONS.................................................................................4

 2.1 Front Panel...............................................................................................................4
 2.2 Rear Panel................................................................................................................5
 2.3 AC Operation...........................................................................................................5
 2.4 Operating Conditions...............................................................................................6
 2.5 Water Ingress and Mounting....................................................................................6

 3 SYSTEM CARRIER-TO-NOISE MEASUREMENT................................................7

 4 SERVICING INSTRUCTIONS...................................................................................8

 4.1 Battery Replacement................................................................................................8

 5 SPECIFICATIONS........................................................................................................9

2

Содержание 5112

Страница 1: ...Model 5112 Multi Carrier Signal Generator User Operation Manual Revision 2 6 Date May 22 2018 ...

Страница 2: ...ymbols Used 3 1 2 Safety Instructions 3 2 OPERATING INSTRUCTIONS 4 2 1 Front Panel 4 2 2 Rear Panel 5 2 3 AC Operation 5 2 4 Operating Conditions 6 2 5 Water Ingress and Mounting 6 3 SYSTEM CARRIER TO NOISE MEASUREMENT 7 4 SERVICING INSTRUCTIONS 8 4 1 Battery Replacement 8 5 SPECIFICATIONS 9 2 ...

Страница 3: ...quency carriers It is enclosed in a rugged portable case 1 1 Symbols Used The following symbols are used in this manual and or marked on the instrument Hazardous areas on the instrument are marked with this symbol Consult this manual to learn the nature of the hazard and proper actions for safe operation Indicates an earth ground terminal Indicates possibility of electric shock Indicates a protect...

Страница 4: ...ument power is provided from the internal battery pack 2 Power on indicator LED LED illuminates when power has been applied to the instrument This powering may be from either the AC receptacle or the DC battery pack 3 AC Charge LED LED illuminates whenever the Model 5112 is connected through the AC receptacle to an AC source The internal battery will be charged when the AC receptacle is connected ...

Страница 5: ... a Type IEC 60320 1 C 13 b 1 5 amp cord rating typical AC operating current 100 mAmps 2 3 AC Operation When operating the instrument from AC power adhere to these rules 1 Warning The appliance coupler is used as the disconnect device Do not position the instrument so that it is difficult to operate the appliance coupler 2 Use only the cord supplied with the unit or an equivalent cord rated for at ...

Страница 6: ...midity 80 up to 31 C 50 at 40 C 5 AC voltage 10 of nominal some temporary over voltage tolerated 6 Transient voltage spikes 2500 Vp 7 Pollution degree 2 or less non conductive pollution 2 5 Water Ingress and Mounting Do not set up or use unit where liquids or other conductive materials are used Ensure that no liquids are spilled into the unit If water or other conductive material enters the enclos...

Страница 7: ...at the point of origin and adjust to system amplitude NOTE If the test carrier is not at system level record the difference in dB and add this quantity to the final reading Now connect a spectrum analyzer or signal level meter to the system test point NOTE For tap levels below 15 dBmV the receiver may require pre amplification to assure sample noise levels are significantly above the receiver nois...

Страница 8: ... from Applied Instruments This pack includes a mounting bracket cable and connector Only the pack from Applied Instruments should be used to ensure safe operation 2 Ensure that the unit is OFF and unplugged 3 Remove the six screws on the sides of the bottom half of the clam shell cover 4 Carefully remove the bottom half of the clam shell and unplug the battery cable from the circuit board while do...

Страница 9: ...e 75 Ohm Spectral Purity spurious harmonic 60 dBc Frequency MHz Max output level per carrier dBmV 5 860 861 1000 1001 1200 For hardware configurations up to 2 carriers 59 57 55 For hardware configurations up to 4 carriers 55 53 51 For hardware configurations up to 6 carriers 52 50 48 Mechanical Operating Temperature Range 0 50 Degrees Celsius Power DC Internal Ni cad Batteries Power AC 120 240V 50...

Страница 10: ...nual Applied Instruments Inc Applied Instruments Inc 5230 Elmwood Avenue Indianapolis IN 46203 USA http www appliedin com Tel 1 317 782 4331 Tel Toll free within USA 800 244 2976 Fax 1 317 786 9665 Email info appliedin com 10 ...

Отзывы: