Utility Closet Connection Locations
-
8
-
IMPORTANT:
Plan and locate plenum, wall plug, drains and thermostat carefully to avoid
interference Hard-to-reach locations will make installation and service difficult!
Reference Dimensions
A
Thermostat cable
B
Power cord: 60" long
if 230VAC or
conduit entrance if 265VAC.
C
Case width and depth: 23-1/8"
D
Case height: 31"
E
Condensate drains: 3/4"connector
• Primary Drain - Centerline of
cutout is approximately 5-1/4"
from left case wall and 8-1/2" from
back case wall.
• Secondary Drain-centerline of
cutout is approximately 6-1/2"
from left case wall and 5-1/4" from
back case wall.
F
Typical wall plug: 6"-12" above case
G
40" min.
Air outlet
Flex duct may be used
for transitions only
Use rigid duct for
90° bends and tees
Outside wall
A
B
C
C
D
E
230/208VAC
Wall receptacle for cord and
plug connection as applicable
Platform
F
G
Connecting the
air outlet
Connecting the
air outlet
WARNING
WARNING
Supply duct is intended to distribute
conditioned air throughout a single
unit on one floor only. Unit space may
be partitioned into rooms within the
same unit, but supply air is not to be
delivered to any other unit.
Provide adequate return air paths for
rooms by established means. Do not
attach a return air duct to the chassis
or outer case.