803877 Rev. 00  

 
 
 
REMOTE THERMOSTAT OPERATION 

 
When the unit is first plugged in, or when recovering 
from a power outage, there will be a random 5 to 15 
second delay before the electronic control powers up. 
The keypad will be totally disabled once the DIP 
switch has been set for remote mode. The unit will 
obey the commands from the thermostat only.  
 
The thermostat will automatically maintain the 
temperature in the room, based on the setting pre-set by 
the user. If the thermostat has only single fan speed 
capability, a decision will need to be made as to 
whether the fan will always run in high speed or low 
speed, and then the appropriate fan speed wiring 
connection can be made at the unit.  
 
All the internal control features of the electronic board 
remain active, except for keyboard and display 
interface functions and room temperature sampling. 
Room temperature is detected at the location of the 
wall thermostat, and is usually a much more accurate 
representation of bulk room temperature. The 
thermostat used may have advanced features beyond 
the basic functions described below. Consult your 
thermostat Installation and Operating Instructions for 
further information. 
 
In addition to controlling room temperature, the room 
thermostat is also used to select whether the unit is to 
be in heating mode, or cooling mode, or in automatic 
changeover between the modes. It also determines 
whether the system is to be ON or OFF, and whether 
the fan is to run continuously, or to cycle with heating 
or cooling demand. 

 

 
 

Figure 2 
 
 

Once a comfortable temperature setting is established, 
no other adjustments are necessary, except for fan 
speed, which may or may not be adjustable on your 
particular thermostat. 

 

 

 

CAUTION

: One side of the unit’s 24-volt control system 

is grounded.  When wiring the thermostat, care must be 
taken not to ground the wires, or drive a nail through the 
thermostat wire bundle, thereby potentially burning out 
the transformer. 

 
 
 
 
 
 
 
 
 
 
 
 

Содержание NAEC SERIES

Страница 1: ...PFLOW PACKAGED TERMINAL AIR CONDITIONER PTAC Cooling with Electric Heat INSTALLATION OPERATION MANUAL IMPORTANT READ AND SAVE THESE INSTRUCTIONS INSTALLATION AND WIRING MUST BE IN ACCORDANCE WITH CEC NEC AND LOCAL ELECTRICAL CODES ...

Страница 2: ...hout an air filter will void the warranty WARNING To avoid bodily injury ensure power is disconnected before removing the air filter as there will be potential exposure to rotating parts Always replace the air filter filter bracket and screw to close off the bottom of the unit to prevent unintended contact with the blower wheels before operating the unit Clean Coils As part of regular servicing cl...

Страница 3: ... on the unit Rating Plate for the specific chassis Wire sizing must also take into account any distance from fuse box or breaker panel to receptacle to prevent excessive voltage drop in undersized wires IMPORTANT Low voltage to the unit will cause compressor starting problems and decrease the performance and reliability of the compressor BRANCH CIRCUIT PROTECTION The Current Rating of branch circu...

Страница 4: ... chassis must be level from side to side and sloped toward the outdoors from front to rear in the order of 1 8 inch per foot once the chassis side flanges are drawn up tight to the wall sleeve using the four flange screws If the sleeve was originally installed with a slope in the bottom of the sleeve in the order of per foot downward from the indoor to outdoor side the chassis will still operate p...

Страница 5: ...TART UP CHECKLIST Note Once the unit is installed it should be checked for proper function by qualified service personnel before turning it over to the User Circuit breakers wire size and electrical connections tight and correct Filter clean and properly in place Condenser air inlet and outlet free of obstructions and no short circuiting of condenser air Unit operated for 20 minutes to prove stabi...

Страница 6: ...ds and then decreases room temperature by 1 degree for every subsequent press of the key F C Key This key toggles the display between Fahrenheit and Celsius temperature modes and affects all displayed temperatures Heat Key The Heat Key toggles the unit in and out of heating mode for every press of the key provided the On Off Key is ON Cool Key The Cool Key toggles the unit in and out of cooling mo...

Страница 7: ...g A factory supplied 24 Volt wiring harness is provided with every unit to facilitate connection to the wall thermostat wiring One end has a multi pin connector which mates with a connector exiting the unit The other end has preinstalled butt splice connectors which play a dual role in insulating any unused connectors and can also be used to make the wire connections for wires that are used The fi...

Страница 8: ...is detected at the location of the wall thermostat and is usually a much more accurate representation of bulk room temperature The thermostat used may have advanced features beyond the basic functions described below Consult your thermostat Installation and Operating Instructions for further information In addition to controlling room temperature the room thermostat is also used to select whether ...

Страница 9: ...d whether the unit is configured for keypad or remote thermostat The protection remains active when the unit is OFF for either keypad or remote thermostat application as long as the unit is plugged in power is available and a heat source is configured in the unit and is working Compressor Short Cycle Protection If the electronic control shuts the compressor down for any reason a 3 minute time dela...

Страница 10: ...only but it can be changed to open with low speed fan operation only by having qualified service personnel re wire the unit as shown on the specific wiring diagram affixed to the unit WARNING The conversion procedure involves exposure to high voltage electrical circuits in the control box in order to make the necessary change to the damper action tied to motor speed and must be performed by qualif...

Отзывы: