2695 Series Operation Manual
EZT-2695-8000/1
Page
34
of
124
Internal Triggering Modes
Other factors such as interrogation pulse length and internal system delays all effect the system
cycle times possible. These are all taken into account in determining if the cycle time required can
be achieved.
Fixed Interval
When in fixed interval mode the unit will attempt to complete the fire sequence in the time set
within the ‘System Cycle Time’ parameter. If this is not possible a message will be displayed.
Auto Calculate
In this mode the system will automatically determine the fastest possible cycle time based on all
the the relevant parameters described at the beginning of this section.
Fastest Possible
In this mode the system will automatically interrogate the next beacon in the fire sequence as soon
as the previous acoustic response is received. This mode will result in a much faster cycle time if
beacons are at close range and will automatically adjust the cycle time as the range of the beacons
increases or decreases.
Fire Sequencing
Fire sequencing can be used to define custom fire sequences rather than a sequential order of
beacon interrogation. With fire sequencing the system may be configured, for example, to fire one
particular beacon more frequently than others.
A sequence of up to 30 entries may be defined.
Available Beacons may be added to the fire sequence by ‘Double Clicking’ on the available beacon
or by selecting the available beacon and pressing the ‘>>’ button.
Beacons may be removed from the fire sequence by ‘Double Clicking’ on them or by selecting
them and then pressing the ‘<<’ button or by clicking the right mouse button and selecting
‘Remove’.
Beacons in the fire sequence may be moved up and down the sequence with the up and down
arrows to the right of the fire sequence section.
If the ‘Start Tracking On Exit’ checkbox is selected, all of the beacons in the fire sequence will be
automatically enabled and interrogation started upon exit from the system configuration window.
Содержание Easytrak Nexus Lite 2683
Страница 1: ...Easytrak Nexus Lite 2695 Series Operation Manual ...
Страница 13: ...2695 Series Operation Manual EZT 2695 8000 1 Page 13 of 124 ...
Страница 85: ...2695 Series Operation Manual EZT 2695 8000 1 Page 85 of 124 Summary Report ...
Страница 86: ...2695 Series Operation Manual EZT 2695 8000 1 Page 86 of 124 Complete Listing of Dataset ...
Страница 88: ...2695 Series Operation Manual EZT 2695 8000 1 Page 88 of 124 ...
Страница 89: ...2695 Series Operation Manual EZT 2695 8000 1 Page 89 of 124 ...