2695 Series Operation Manual
EZT-2695-8000/1
Page
103
of
124
ORE Trackpoint STD-EC W/PR Data string
The
simplified
STD-EC W/PR
string has
80
characters including carriage return and line feed.
i*hh:mm:ss*ccc*bbb.b*rrrrr.r*xxxxxx.x*yyyyyy.y*zzzzz.z*-ttttt.t*EE*RRR.R*PPP.PCL
Description
String code
Beacon identification
i
Hour
h
Minute
m
Second
s
Compass
c
Bearing
b
Slant range
r
X (or Eastings)
x
Y (or Northings)
y
Z
z
Telemetry
t (always 0.0)
Error
E
Roll
R
Pitch
P
Carriage return (CR)
C
Line Feed (LF)
L
Note * = space.
Note fields are space separated. Leading 0’s (except time) are space filled. When in GPS mode,
the X, Y and Z fields automatically expand to take the full GPS data value.
Example:-
2*23:59:59*359*359.9**1234.5*-10000.0*-10000.0*10000.0******0.0*00**1.2* 2.1CL
If the signal is lost, the following string is outputted.
2*23:59:59*359***-.-*****-.-******-.-******-.-*****-.-******-.-06***-.-***-.-CL
Note * = space.
Error codes
No error
00
Lost signal
06