Compatt Menu
This software module enables the PAM to communicate with a Sonardyne Compatt MK4, upon
activation by an update code this module is available.
An electrostatic loop can be used to communicate with the Compatt. Connect the test loop to
the transducer connector of the Pam and put the loop around the Compatt’s transducer.
Set Compatt Address
To enable communications with the Compatt, the address needs to be entered. From the Compatt
main menu press F2. The following menu will be displayed, enter the address of the Compatt.
Press F1 to Test, the result of the test interrogation is displayed in the Status line.
Note:
If the Compatt has the address 201 marked on the bottle then the PAM should be set
so that it shows 0201