~ 14 ~
DRY CYCLE
11.
Combo will not dry
If the laundry is cold and wet at the end of the dry cycle, please check for as following.
11.1
Thermostats are open
: Disassemble the work top and check for the continuity between the
terminals of TH2-3 & TH2-4 at room temperature (see figure below). If it is closed, then check
for the dryer heaters. If it is opened, check for the turbo fan, and then push down the reset
button.
11.2
Turbo fan not work
.
11.2.1
Thermostat open
: Check for the continuity between the terminals of TH1-1 & TH1-2 at
room temperature (see figure below). It should be closed, if not, replace a new one.
11.2.2
Poor wire connection
: Check for the wiring to the turbo fan (see figure below).
11.2.3
The turbo fan is defective
: Check for the resistance between two terminals of TF-1 &