background image

Appleton • 1.800.621.1506 • www.appletonelec.com

303302 Rev. G 02/16 • Page 3 of 12

Drawings

Figure 1: FSQC 30 A Dimensions 

(Shown with flip cover for maximum space consideration)

3.12"

7.92 CM

6.36"

16.15 CM

1.25"

3.17 CM

10.44"

26.52 CM

6.42"

16.30 CM

5.02"

12.75 CM

MOUNTING HOLES
0.375" DIA (2X)

2 CONDUIT ENTRIES (TOP & BOTTOM)
SIZE 1-11 1/2 NPT OR 3/4-14 NPT WITH
REDUCER

Figure 2: FSQC 30 A Details & Parts List

2

5

7

SWITCH TERMINAL
SCREWS FOR LINE
WIRE CONNECTIONS

FACTORY WIRED

12

3

4

1

14

15

16

6

10

13

11

9

8

17

18

Table 1:  FSQC 30 A Parts List

Item #

Part Description

Item #

Part Description

Item #

Part Description

1

Receptacle flip cover

*

7

Line side pressure screws

13

Disconnect switch

2

Enclosure cover

8

ON/OFF nameplate

14

Ground lug & screw

3

Locking screw

9

Load side pressure screws

15

Ground lug wire screw

4

Receptacle housing body

10

Switch actuating fork

16

Ground lug wire

5

Enclosure

11

Switch actuator screws

17

Screw

6

Switch plate

12

Switch mounting screws

18

Screw cover assembly

*

*

Choose Item #1 or #18 based on the application.

Содержание FSQC 30 A

Страница 1: ... design means that all electrical switching is done with an internal switch The plug cannot be engaged or disengaged with the receptacle when the switch is ON Positive Contact Brass contacts have integral springs for positive maintained electrical contact Receptacle face enables the engagement of plugs for a weatherproof union Positive Ground Grounding terminal for Style 2 receptacle makes first b...

Страница 2: ...art of the receptacle appears to be missing broken or show signs of damage discontinue use immediately This condition could cause serious or fatal personal injury due to electrocution and or equipment damage Repair with the proper replacement part s before continuing service WARNING ENVIRONMENTAL To prevent ignition of hazardous atmospheres do not use in Class II Group E locations that contain ele...

Страница 3: ...INAL SCREWS FOR LINE WIRE CONNECTIONS FACTORY WIRED 12 3 4 1 14 15 16 6 10 13 11 9 8 17 18 Table 1 FSQC 30 A Parts List Item Part Description Item Part Description Item Part Description 1 Receptacle flip cover 7 Line side pressure screws 13 Disconnect switch 2 Enclosure cover 8 ON OFF nameplate 14 Ground lug screw 3 Locking screw 9 Load side pressure screws 15 Ground lug wire screw 4 Receptacle ho...

Страница 4: ... List 8 11 14 15 6 7 10 12 13 1 4 3 2 5 LINE SIDE GROUND LUG FACTORY WIRED 15 LOAD SIDE 9 16 17 18 Table 2 FSQC 60 A Parts List Item Part Description Item Part Description Item Part Description 1 Receptacle flip cover 7 Line side pressure screws 13 Disconnect switch 2 Enclosure cover 8 ON OFF nameplate 14 Ground lug screw 3 Locking screw 9 Load side pressure screws 15 Ground lug wire screw 4 Recep...

Страница 5: ...e housing body Item 4 This prevents the enclosure cover Item 2 from rotating and simultaneously locks the receptacle interior rotation also toggling of the switch 2 Turn the enclosure cover counterclockwise outward to completely remove it from the enclosure 3 After removal we recommend that the enclosure cover be placed with the outer surface down on a clean surface Protect the enclosure cover wit...

Страница 6: ...o ensure that the system does not have any short circuits or unwanted grounds Clean the Receptacle Cover Enclosure Before replacing or closing the receptacle cover it is strongly recommended that all dirt debris and other foreign materials be removed from the enclosure interior This action should be taken to help keep the breathers and drains from being plugged by these materials 1 Make sure the e...

Страница 7: ...s provided in the receptacle collar and enclosure for the use of padlocks to lockout unauthorized movement of the plug from the OFF position The receptacle collar must be fully rotated ON OFF as indicated on the nameplate to have the switch turn ON OFF properly This can be checked by listening to the switch click during each ON OFF cycle Maintenance WARNING Electrical power must be turned OFF befo...

Страница 8: ...te that the receptacle is OFF when the disconnect switch is in the OFF position 4 Take the disconnect switch out of the enclosure Loosen the load side pressure screws Item 9 and remove the load side wires 5 Replace the disconnect switch with the same type as shown in Table 5 and reverse the steps above Make sure to reconnect the wires to the same locations as before disassembly Table 5 Disconnect ...

Страница 9: ...8 Screw cover assembly PTTC30 PTTC60B 1 Lubricant TLC 3 TLC 3 1 Instruction sheet 69303302000 69303302000 1 Appendix A FSQC Receptacle Covers Ratings FSQC with Standard Flip Cover is UL Listed for Class I Division 1 and 2 Groups B C D Class II Division 1 and 2 Groups F G NEMA Type Designation TYPE 3R Raintight TYPE 5 NEMA 12 Hazardous Area FSQC with Optional Screw Cover is UL Listed for Class I Di...

Страница 10: ...A receptacle uses catalog number AUX30 auxiliary switch FSQC5640 60 A receptacle uses catalog number AUX60 auxiliary switch Figure 6 Auxiliary Switch Assembly Parts List for 30 A 1 2 3 4 5 Table 8 Auxiliary Switch Parts List Item Part Description Appleton Part Number Quantity per Assembly 1 Mounting bracket 69303338000 1 2 Auxiliary switch 69303320000 1 3 Screw 4 40 x 1 2 69P05117000 2 4 Mounting ...

Страница 11: ...Properly crimp the terminals Installing the Auxiliary Switch Field Installations 1 Referring to Figures 6 or 7 mount the auxiliary switch Item 2 to the mounting bracket Item 1 using the two screws Item 3 2 Referring to Figures 6 or 7 mount the mounting bracket to the receptacle enclosure using the two mounting screws Item 4 3 Adjust the location of the mounting bracket as needed to ensure that the...

Страница 12: ...authorized to extend Appleton s warranties to any consumer While every precaution has been taken to ensure accuracy and completeness in this manual Appleton Grp LLC assumes no responsibility and disclaims all liability for damages resulting from use of this information or for any errors or omissions Specifications are subject to change without notice The Appleton and Emerson logos are registered i...

Отзывы: