VTA
EN
1-3 Electrical Specifications
Accuracy is given as ± (% of r counts of least
significant digit) at 23°C ± 5°C, with relative humidity
Less than 80% R.H., and is specified for 1 year after
calibration.
•
Condition of Auto Power On :
With batteries fitted :
- > 3.0V or < -8.0V between L2 and L1
- Detect AC signal by Single Pole
- Continuity
Without batteries :
> | ±35.0V DC | or > 45.0V AC between L2 and L1
•
Auto Power Off :
The Meter automatically turns off if one of the
following conditions are met for about 10 seconds
- The Auto Power On condition is not met.
- Both buttons are not pressed.
The Meter automatically turns off if one of the
following conditions are met for about 30 seconds
- The resistance is OL when the Meter is in Resistor
mode.
- The current is < 1.0A when the Meter is in Ampere
mode
• For > 300V, Time rating (tr): 30 seconds;
Recovery time (rt): 240 seconds
• AC Function
- ACV and ACA specifications are ac coupled, true
RMS.
- For non-sinusoidal waveforms, Additional Accuracy
by Crest Factor (C.F.) :
Add 1.0% for C.F. 1.0 ~ 2.0
Add 2.5% for C.F. 2.0 ~ 2.5
Add 4.0% for C.F. 2.5 ~ 3.0
- Max. Crest Factor of Input Signal:
3.0 @ 5000 counts
1.5 @ 10000 counts
14
Содержание VTA
Страница 7: ...VTA EN Continuity Check Resistor Mode 6 ...
Страница 22: ...VTA TC 順時針相位順序 L1 L2 L3 右邊 相位旋轉測試 逆時針相位順序 L1 L3 L2 左邊 來源 端點 緊握 來源 端點 緊握 21 ...
Страница 24: ...VTA TC 連續性確認 電阻器模式 23 ...
Страница 27: ...VTA TC 手電筒 自行偵錯測試 Powering ON Press 2sec 警告 於自行偵錯測試時若發現異常 請勿使用電表 OFF Press or 按壓 2 秒 或 按壓 關閉 26 ...
Страница 39: ...VTA SC 顺时针相位顺序 L1 L2 L3 右边 相位旋转测试 逆时针相位顺序 L1 L3 L2 左边 来源 端点 紧握 来源 端点 紧握 38 ...
Страница 41: ...VTA SC 连续性确认 电阻器模式 40 ...
Страница 44: ...VTA SC 手电筒 自行侦错测试 Powering ON Press 2sec 警告 于自行侦错测试时若发现异常 请勿使用电表 OFF Press or 按压 2 秒 或 按压 关闭 43 ...
Страница 56: ...VTA JP 時計回りのフェーズシーケンス L1 L2 L3 右 相回転試験 反時計回りの位相シーケンス L1 L3 L2 左 スコア ターミナル 手でしっ かり握る スコア ターミナル 手でしっ かり握る 55 ...
Страница 58: ...VTA JP 導通チェック 抵抗モード 57 ...
Страница 75: ...VTA RU Проверка Непрерывности Режим Резистора 74 ...