11
(4) AC Current
Range
Resolution
Accuracy
Voltage Burden
200 µA
0.1 µA
±(1.5%rdg + 3dgt)
40Hz — 500Hz
600mV rms max.
2mA
1 µA
20mA
10 µA
200mA
100 µA
* 20A
10mA
±(2.5%rdg + 3dgt)
40Hz — 500Hz
900mV rms max.
AC Conversion Type :
Average sensing rms indication.
Overload Protection :
1A (500V) fast blow fuse for µAmA input.
16A(500V) fast blow fuse for 20A input.
* 20A Range : 30 seconds maximum above 10A.