User Manual: Multispot GII-HQ5020
V2.00 (08-2015)
20
displayed value to 3 times. If no change is made for 0,5 sec. or longer or the MODE
button is pressed the relative settings become active. The display will only show the
values presently being viewed or changed. After 30 sec. of no alterations or if the
MODE button is pressed the display returns to show “GDMX”.
IN PRES (preset mode), the channel assignment is as follows:
CH1 = 000-255: Color presets ST1….ST25 as in Static Color Mode [If CH3 < 050]
CH1 = 000-127: Fade presets FP0…FP7 as in Switch Pattern Mode [If CH3 ≥ 050]
CH1 = 128-255: Fade presets SP0…SP8 as in Fade Pattern Mode [If CH3 ≥ 050]
CH2 = 000-255: Master Dimmer 0-100%
CH3 = 000-049: Color preset mode selection (color by CH1)
CH3 = 050-255: Pattern preset mode selection and speed setting (pattern by CH1)
CH4 = 000-049 Strobe off
CH4 = 050-255 Strobe with adjustable speed (050=slow / 255=max. speed)
NOTE:
Whenever a DMX signal is received, the “D” tab in the display is lit – this is valid
for all DMX-related modes.
The DMX channel setting is global – if you change the control mode/channel scheme
later, the DMX start address will remain valid, but the number of consumed channels
may change.
DO NOT try to leave the control mode/channel scheme choice by pressing the left/right
arrow buttons; this would change the control mode/channel scheme to the next
subsequent choice. Always leave this mode by either pressing the MODE button or by
simply waiting until the display returns to show “GDMX.
■ COLOR BALANCE
In this Mode you can define your individual fixture’s Color Balance by setting a
maximum brightness for each LED colour giving you the individual color balance you
desire. Press the MODE button until the display shows
“CBAL”
. Use the left/right arrow
buttons to select any of the following options: „Rxxx“, „Gxxx“, „Bxxx“, „Axxx“ and „Wxxx“
with „xxx“ being values between 200 and 255. Value settings below 200 are disabled to
avoid unwanted output reduction of the fixture. If you want to change the maximum
output of the colour being displayed use the +/- buttons to do so. For control purposes
all LED's are lit with their chosen maximum value. All changes made become effective
immediately. If pressing the MODE button during editing a color level, the display
returns to ‘CBAL’.
Note: Any settings made in this mode will influence the overall color balance of the
fixture (in all available operation modes – also DMX). To make sure that several fixtures
User Manual: Multispot GII-HQ5020
V2.00 (08-2015)
5
4. The surface of the device may get hot during operation, and heat
sink areas may reach to or exceed the limits of EN60950. Do not
touch heat sink areas of the device during operation, and allow 20
minutes of cool-down time after powering off before touching.
5. If fluids have spilled into the unit or small parts have intruded the
unit, immediately switch off the unit and hand it over to the
authorized service for a security check.
6. Disconnect the unit from AC supply by pulling the AC plug out of
the wall outlet or the unit’s AC socket during a thunder-storm in
order to avoid any damage on the unit due to AC voltage peaks.
7. In cause of not correct function of this unit or damaged AC cord or
other damaged parts, pull immediately the AC plug out of the wall
outlet and hand the unit over to the authorized service for a
security check.
8. To meet all aspects of functionality and security during mainte-
nance work to be preformed on this unit, all parts should be
replaced by genuine spare parts. Consequently, take care of your
dealer or maintenance company to be authorized by the
manufacturer.
■
Health advice
This unit produces and absorbs electromagnetic radiation. The strength of radiation and
the sensitivity for disturbing interference matches the CE and FCC requirements. A
corresponding sign is printed on the backside of the unit. Any change or modification
may affect the behavior of the unit concerning electromagnetic radiation, with the CE
requirements eventually not to be met any more. The manufacturer takes no
responsibility in this case.
■
Functional advice
This unit is immune to the presence of electromagnetic disturbances – both conducted
and radiated - up to a certain level. Under peak conditions, the unit is classified to show
a “class C” performance criteria and may encounter temporary degradation or loss of
function which may need manual help to recover. In such case, disconnect the AC
power from the unit and reconnect it again to recover.
■
Environmental advice
This unit is built to conform to the ROHS standards and the WEEE
directive 2002/96/EC of the European Parliament and of the Council of
the European Union. Under these regulations, the product shall not be
discarded into regular garbage at the end of its life, but shall be returned
to authorized recycling stations.
Содержание MultiSpot HQ5020
Страница 1: ...Exclusive USA Distributor MultiSpot HQ5020...
Страница 2: ......
Страница 12: ...ed ers he im r 0 ed es he xx he is 0 ers ur will im ng ng an User Manual Multispot GII HQ5020 V2 00 08 2015 9...
Страница 13: ...User Manual Multispot GII HQ5020 V2 00 08 2015 10 U V2 U...
Страница 26: ......
Страница 27: ......