background image

User Manual: Multispot GII-HQ5020

    

                                       

 

V2.00 (08-2015)                                                                                                                                                

14

 

weight of the device when installing the unit. This secondary safety attachment 

should be installed in a way that no part of the installation can drop more than 

20cm if the main attachment fails. 

  Never stand directly below the device when mounting, removing, or servicing the 

fixture. Make sure the area below the installation place is free from unwanted 

persons during rigging, de-rigging and servicing. 

  The operator has to make sure that the safety-relating and machine-technical 

installations are approved by an expert before using them for the first time. The 

installations should be re-inspected every year. 

  Make sure to comply with applicable cooling requirements if any.  

 

■ 

Getting started: making AC supply connections

 

 

 

 

 

 

 

Risk of fire / Safety risk 

• The MULTISPOT-GII-HQ5020 LED requires an AC power source with 

sufficient power carriage and correct grounding to ensure safe 

operation. The AC power source must be equipped with a circuit 

breaker and earth leakage detector. Make sure to only use compliant 

AC supply lines.  

• The MULTISPOT-GII-HQ5020 LED has an AC outlet that is designed 

to carry loads of no more than 10A. Make sure that all connected 

devices in a chain fed by the first device do not exceed a maximum of 

10A current consumption.  

■ 

Getting started: making DMX control connections

 

 

Connect the MULTISPOT-GII-HQ5020 to a suitable DMX controller where needed, and 

interconnect several units by means of their DMX In/Outputs as required. The last unit 

shall be fitted with a proper 120 Ohm termination resistor-equipped DMX-plug as 

shown in below drawing. Please make sure that all used DMX cables comply to below 

standard: 

 

 

User Manual: Multispot GII-HQ5020

    

                                       

 

V2.00 (08-2015)                                                                                                                                                

11

 

■ 

Getting started: changing the lens panel (only if required)

 

 

Your MULTISPOT-GII-HQ5020 has been factory-fitted with the default lens panel. If 

you need to exchange the lens panel to achieve specific dispersion angles, please 

contact your distributor for availability information of other lens panels and follow the 

below procedure to exchange the lens panel if required.   

 

 

Reliability risk:

 Exchanging the lens panel in an inappropriate manner 

may defeat the waterproof capabilities of the fixture and may void any 

warranty of the manufacturer if water intrudes into the unit. It is 

essential to follow the below instructions to maintain the waterproof 

capabilities of the fixture and its product warranty subsequently.  

Before you start to exchange the lens panel, please make sure that: 

  the unit is completely dry, and at room temperature.  

  the location chosen to exchange the lens panel does not have more than 40% 

relative humidity and the temperature during the exchange does not exceed 40 

degrees Celsius. These parameters are important to avoid later condensation of 

the water contained in the environmental air when the unit works at lower outside 

temperatures. 

  The screw driver used to dismantle and re-assemble the unit is properly matching 

the screws to avoid any damage to the screws. This will require a 4mm HexInsert 

screw driver.  

  The screw driver has an in-built torque measurement or you have other torque-

measurement devices on hand to make sure that screws are fastened with the 

right torque during re—assembly.   

 

To exchange the lens panel, follow the below procedure: 

 

1)  Make sure the unit is switched off and cooled down for at least 30 minutes 

after last operation. Detach all cables.  

2)  Lay the unit face-down on a stable but soft surface (like a table covered with a 

towel), and remove the 8 screws which connect the main fixture body with the 

front frame (Illustration step A).  

3)  Turn the unit around and lift off the front frame, while you hold down the front 

glass. Holding down the front glass is a safety precaution, since due to the 

adhesion of the soft rubber of the front glass seal, it could potentially happen 

that the front glass including its rubber seal “stick” to the front frame and fall 

out during the removal procedure, potentially damaging the front glass. 

4)  Carefully lift off the front glass including the glass seal (Illustration step B).   

5)  Unscrew and remove the 5 lens panel screws holding the lens panel.  

6)  Remove the lens panel by vertical lifting it off. It is important to expedite this 

process absolutely perpendicular to the LED panel, as excessive tilting of the 

lens panel versus the LED panel can damage the LEDs. Use both hands and 

the provided finger grip points and lift off the lens panel.  

Содержание MultiSpot HQ5020

Страница 1: ...Exclusive USA Distributor MultiSpot HQ5020...

Страница 2: ......

Страница 3: ...nd value Focused on you our goal is to ensure unparalleled support from the initial conversation to after sales service Our lighting experts and engineers will consult with you on ways to use our stan...

Страница 4: ...020 High Power DMX Controlled LED light source For firmware 50 010 0088 00113 1 03 MS GII HQ5020 RevN Updated versions of this document may be available at WWW MULTIFORM LIGHTING COM RevB 08 2015 Orde...

Страница 5: ...The Multispot GII is a high power DMX controlled LED light source for both indoor and outdoor applications which range from architectural illumination to stage lighting Available in various LED config...

Страница 6: ...h greatest care Punches big forces and heavy vibration may damage this product mechanically Protection from eye injury 1 Warning Depending on the configuration of the device this device may reach or e...

Страница 7: ...w at least about 0 15m 6 ins between this unit and other devices or a wall to allow for proper cooling 3 Take always care of sufficient air convection in the unit s environment to avoid overheating Ma...

Страница 8: ...re parts Consequently take care of your dealer or maintenance company to be authorized by the manufacturer Health advice This unit produces and absorbs electromagnetic radiation The strength of radiat...

Страница 9: ...r MULTISPOT GII HQ5020 has been factory fitted with connectors for both AC In Out and DMX In Out This configuration can be changed with comparatively little effort into an IP65 compliant outdoor versi...

Страница 10: ...hat screws are fastened with the right torque during re assembly To expedite the connector change you will need Multiform s outdoor conversion kit for this unit which is available from your distributo...

Страница 11: ...cover with the electronics assembly to face its inside Pull the cable stumbs far enough out to allow skinning of the leads inside the cables 12 Skin the separate leads of both the DMX and AC cables a...

Страница 12: ...ed ers he im r 0 ed es he xx he is 0 ers ur will im ng ng an User Manual Multispot GII HQ5020 V2 00 08 2015 9...

Страница 13: ...User Manual Multispot GII HQ5020 V2 00 08 2015 10 U V2 U...

Страница 14: ...e the unit is properly matching the screws to avoid any damage to the screws This will require a 4mm HexInsert screw driver The screw driver has an in built torque measurement or you have other torque...

Страница 15: ...Put the 5 lens panel screws back into place which hold the lens panel and tighten them with 0 50 0 55Nm torque 11 Check whether the front glass seal smoothly surrounds the front glass in proper positi...

Страница 16: ...requirements of the used power supply if any Hanging Rigging ceiling mounted operation Risk of injury Overhead mounting requires extensive experience like calculating working load limits knowledge in...

Страница 17: ...AC supply connections Risk of fire Safety risk The MULTISPOT GII HQ5020 LED requires an AC power source with sufficient power carriage and correct grounding to ensure safe operation The AC power sour...

Страница 18: ...Button 5 Button 6 DISPLAY Sound to Light Indicator 7 DISPLAY 4 Digit Message Display Area 8 DISPLAY Indicator 9 DISPLAY Indicator 10 DISPLAY ARROW Indicators 11 DISPLAY DMX Signal Presence Indicator...

Страница 19: ...mming level will remain as last set The same happens if the color preset is changed by the left right arrows in this case the dimming level mode is left immediately and the dimming level will remain a...

Страница 20: ...SP8 yellow green turquoise blue candy red SP2 blue red SP9 Strobe red SP3 yellow red SP10 Strobe green SP4 candy lime SP11 Strobe blue SP5 candy blue SP12 Strobe white SP6 candy turquoise Use the left...

Страница 21: ...defined as follow Pattern Steps Pattern Steps FP0 red green FP4 candy lime FP1 blue green FP5 candy blue FP2 blue pink red FP6 candy aqua turquoise FP3 yellow lime red FP7 red yellow green turquoise...

Страница 22: ...ge can be mixed The attempt to use an external DMX controller as a master with all connected Multispot GII set to SLA mode will deliver unexpected and or confusing results use the GDMX setting instead...

Страница 23: ...the number of consumed channels may change DO NOT try to leave the control mode channel scheme choice by pressing the left right arrow buttons this would change the control mode channel scheme to the...

Страница 24: ...e UI will remain unlocked To unlock a locked unit press the left and the right arrow buttons simultaneously Auto Display off Use the left right arrows until the display shows ADIS Press any of the but...

Страница 25: ...Secondary 25 degrees DMX Control 3 7 Channels IP Rating 20 indoor 65 outdoor Mains Input AC90 250V 50 60Hz Power supply type switch mode Power consumption 95W Fuse internal see service manual DMX conn...

Страница 26: ......

Страница 27: ......

Страница 28: ...Apollo Design Technology Inc 260 497 9191 ApolloDesign net Copyright 2016 Apollo Design Technology Inc 2 16 MultiSpot HT5020...

Отзывы: