Содержание AAN-4

Страница 1: ...anual contains confidential information and may only be reproduced or distributed with the written consent of Apollo Security Sales Inc 2011 Apollo Security Inc AAN 4 Hardware Manual Revision Date 19 OCT 2011 ...

Страница 2: ...en taken in the preparation of this document Apollo Security assumes no responsibility for errors or omissions or for damages resulting from the use of information contained in this document or from the use of programs and source code that may accompany it In no event shall the publisher and the author be liable for any loss of profit or any other commercial damage caused or alleged to have been c...

Страница 3: ...nd a ESD wrist strap Work stations are available from various vendors including the 3M company FCC Compliance Statement This device complies with Part 15 of FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired operation This equipment ha...

Страница 4: ... Connectors 12 4 LEDs 12 Start Up Mode 13 Normal Operation 13 5 Firmware 13 6 Memory Backup 14 7 Additional Installation Information 14 Mounting Holes Part III System Wiring 17 17 1 Power 17 2 Grounding 17 DC Ground 17 RS 485 Signal Ground SG 18 Safety Earth Ground 18 Grounding System 18 Grounding Potential Difference Checks Before Connecting 18 3 Host Communication Connection 19 Serial 20 Network...

Страница 5: ...ADA External High Security Relays 32 Strike Wiring External ADA 10 11 High Security Relay 33 Additional Output Relay Wiring 34 ADA DIP Switches Jumpers 36 7 General Alarm Inputs 36 Cabinet Tamper Part IV Software Configuration Utilities 38 38 1 ENI 100 IP Programming 39 InitAAN 42 Web Page 45 Telnet Part V Troubleshooting 49 49 1 Communications 49 2 Reader Keypad 49 3 Input Zones 49 4 Output relay...

Страница 6: ...Part Introduction I ...

Страница 7: ...tions of the system is stored within the AAN 4 s internal memory and does not rely on a constant connection to the host computer The AAN 4 provides interface connections for a variety of card reader technologies including proximity biometric bar code and infrared readers Any card reader with standard Wiegand or mag stripe output can be connected to the AAN 4 Provided for each of the four readers a...

Страница 8: ...f the card and PIN match o Locked No access granted Reader ignores all cards and PIN entries o Unlocked Door strike is continuously energized and the door contact input is not monitored Access is not controlled o Facility Code The entire card contents are read by the AAN 4 but only the Facility Code is checked and if it matches a Facility Code downloaded from the programming host access is granted...

Страница 9: ... 1 3 Programming Host Logical Diagram Typical System Layout with RS 485 Connections Several AAN 4 panels can be connected to one host on an RS 485 line using different device addresses Field devices on the same line must also have unique addresses ...

Страница 10: ...Part Hardware Layout II ...

Страница 11: ...rk configuration AAN 4N the removable port driver module is replaced with an ENI 100 Network Interface module 2 1 Terminal Connectors The AAN 4 has 9 terminal blocks for connecting power reader and alarm inputs and relay output connections The connection terminals are factory equipped with removable screw down quick connectors which are easily removed from the board by firmly grasping the connecto...

Страница 12: ...eturn EPBR Reader 1 Exit Push Button Normally Open 12 Exit Push Button EPB 13 Door Contact Return DCR Reader 1 Door Contact Normally Closed 14 Door Contact DC 15 Ground Reader Power GND Reader 2 Device Connections 16 Green LED Control GLED 17 Beeper Buzzer Control BZR 18 Wiegand Data 1 D1 19 Wiegand Data 0 D0 20 VDC Reader Power VDC 21 Red LED Control RLED 22 Yellow LED Control YLED 23 Auxiliary I...

Страница 13: ...Door Contact Return DCR Reader 3 Door Contact Normally Closed 42 Door Contact DC 43 Ground Reader Power GND Reader 4 Device Connections 44 Green LED Control GLED 45 Beeper Buzzer Control BZR 46 Wiegand Data 1 D1 47 Wiegand Data 0 D0 48 VDC Reader Power VDC 49 Red LED Control RLED 50 Yellow LED Control YLED 51 Auxiliary Input Return AUXR Reader 4 Auxiliary Input Normally Closed 52 Auxiliary Input A...

Страница 14: ...onnection 73 Normally Open NO 74 Normally Closed NC 75 Common C Door 3 Auxiliary Relay Connection 76 Normally Open NO 77 Normally Closed NC 78 Common C Door 4 Auxiliary Relay Connection 79 Normally Open NO 80 Normally Closed NC AAN 4 Device Connections 81 Power Input VIN Power Input Connection 82 Ground GND 83 Tamper Input TMP Cabinet Tamper Input Normally Closed 84 Tamper Input Return GND 85 20 m...

Страница 15: ...FF ON OFF OFF 4 OFF OFF ON OFF ON 5 OFF OFF ON ON OFF 6 OFF OFF ON ON ON 7 OFF ON OFF OFF OFF 8 OFF ON OFF OFF ON 9 OFF ON OFF ON OFF 10 OFF ON OFF ON ON 11 OFF ON ON OFF OFF 12 OFF ON ON OFF ON 13 OFF ON ON ON OFF 14 OFF ON ON ON ON 15 ON OFF OFF OFF OFF 16 ON OFF OFF OFF ON 17 ON OFF OFF ON OFF 18 ON OFF OFF ON ON 19 ON OFF ON OFF OFF 20 ON OFF ON OFF ON 21 ON OFF ON ON OFF 22 ON OFF ON ON ON 23...

Страница 16: ...erface This setting must be the same for all devices on the communication line connected to this port Input Monitor Mode Specifies whether all inputs on the interface Auxiliary inputs door contacts exit push buttons will be monitored by comparing the resistance value of the input line with the expected value ON In the event of tampering with the input the interface will report the specific type of...

Страница 17: ...ng on the type of communication required on the port The device is connected to the serial communications line using the Host Communication Connection see Table 2 1 If RS 232 is used one device may be connected to the line If RS 485 is used a maximum of 16 AAN 4s can be connected on one communications line each having a unique address from 0 to 31 NOTE AAN 4 controllers can NOT be used on the same...

Страница 18: ...rammable flash memory In the event that the firmware must be re installed or updated no chips need to be replaced on the panel The new program can be loaded from the host via special software For normal operation it is not necessary to update the firmware If this becomes necessary contact your Apollo support representative Firmware updating should only be done under the recommendation and guidance...

Страница 19: ...1 Apollo Security Inc 2 7 Additional Installation Information 2 7 1 Mounting Holes Four holes are provided for mounting the AAN 4 Standoffs should be used when mounting in order to protect the underside of the circuit board ...

Страница 20: ...ardware Manual 2011 Apollo Security Inc Figure 2 7 1 AAN 4 Mounting Holes Location of mounting holes for the AAN 4 is shown in scale Note that the drawing will not print the exact size of the actual circuit board ...

Страница 21: ...Part System Wiring III ...

Страница 22: ...it may be necessary to interrupt the supply of power to allow the fuses to reset 3 2 Grounding Special care should be taken when grounding the AAN 4 controller and other devices connected to it via the direct communication lines Each device must be grounded to provide ESD protection personnel safety and signal reference for devices which communicate with each other Grounding the reader provides a ...

Страница 23: ...In a system with a PC personal computer it is likely that the PC already provides the DC Ground connection to the Ground System earth ground Care must be taken NOT to create more ground connections In systems with multiple PCs communicating to Apollo Hardware via direct connection the ground potential must be the same for inter connection or some form of isolation must be provided 3 2 5 Grounding ...

Страница 24: ... Data Rate 20K Bps 10M Bps After choosing the method of communication the proper wiring must be made from the host to the controller Typically the communication will be from a standard 16550 UART COM port on a PC which will be connected directly to the AAN 4 in the case of RS 232 or through the use of an adapter or add on PC card to achieve the RS 485 signal The communications wiring must cross ov...

Страница 25: ...via a network switch hub or other network connection device The ENI communicates at 10 100Mbps with the TCP IP protocol The IP address of the ENI should be specified in the host software and the host will initiate communications with the ENI which will translate the messages to the AAN 4 Routing with ENI 100 If the ENI has an IP address that is not on the same subnet as the host computer there is ...

Страница 26: ...o the proper signal 3 3 2 1 2 Hardware Layout ENI 100 Side View TTL Serial Connector RJ 45 Ethernet Connection Mounting Stand off Figure 3 3 2 1 ENI 100 Hardware Layout 3 3 2 1 2 1 Connectors TTL Serial Connector 12 pin connector located on the underside of the ENI used for connection to port J12 on the AAN 4N Communication AND power are supplied through this connector RJ 485 Jack For communicatio...

Страница 27: ...web server For setting additional security parameters see the Telnet section of Software Configuration Utilities To open the web page configuration type the IP address of the ENI in the address bar of your web browser Do not preface the address with www You should see the following screen where the username and password must be entered The default username password is blank thus if it was not prev...

Страница 28: ...e AAN 4 Other settings may be necessary or desired according to your configuration IP Address IP address of the ENI 100 This is a static IP address so the network administrator must verify that it will not be used elsewhere in the system Telnet Enable When checked enables Telnet access to the web page and configuration files stored in the ENI Telnet Password Password that must be entered to log in...

Страница 29: ...auto connect Required Not enabled Gateway Address and Subnet Mask These are used to connect to another ENI that is not on the same network when the Auto Connect box is checked Set all values to 0 to disable this feature Required Not enabled UDP HOST LIST From the main screen clicking the UDP Host List Button will display the Host List configuration This feature is not used by the ENI 100 when used...

Страница 30: ...f the reader at a minimum the Data 0 and Data 1 wires must be connected from the reader to the AAN 4 and power supplied to the reader LED and beeper control lines do not have to be connected but in this case the LEDs and beeper may not function on the reader Brown LED Red 5 VDC Green Data 0 White Data 1 Yellow Buzzer Orange LED Black Ground Yellow LED If used Shield READER 3 CONNECTION Door Contac...

Страница 31: ...is effectively prevents all alarm generation This situation is not very secure and should not be used in any situation that requires maximum security Unsupervised normally open inputs will have an open circuit infinite ohms when the circuit is in the secure state and a short circuit 0 ohms when the circuit is in the unsecured state The same situation will occur as stated above if the wires are cut...

Страница 32: ... reason not as a result of a valid card or PIN use or exit button activation the reader will generate a Forced Open message If the door is opened as a result of a valid access request or exit button activation but not allowed to close within the programmed held open time a Held Open alarm will be generated The reader may also be configured from the host software to allow early strike relay shutoff...

Страница 33: ...hat exit must be obtainable from all doors regardless of proper operation of the access control system and without any prior knowledge of the system operation This normally means that some form of emergency crash bar or manual door release be provided IT IS THE RESPONSIBILITY OF THE INSTALLER TO INSURE ALL LOCAL CODES ARE FOLLOWED DURING INSTALLATION 3 5 4 Auxiliary Alarm Inputs This is a normally...

Страница 34: ...re that 2 amps to control a separate external relay capable of switching the required amount of current must be installed The AAN 4 provide two methods of strike control for each reader The first method is by use of the internal strike relay Four such relays are provided on the AAN 4 one for each reader input Each is rated for switching 2 amps at up to 24 volts DC Connection of this internal relay...

Страница 35: ... allows for simple connection of the door strike without requiring installation of external ADA 10 11 relay modules This will result in reduced installation costs at the expense of increased security Use of the external high security relay modules ADA 10 11 will provide increased security on the strike output The diagram below illustrates connection of a DC powered Fail Secure door strike This typ...

Страница 36: ...plus valid PIN valid PIN entry only etc The reader will also permanently activate the strike relay if commanded by the host software to be unlocked The reader may also be configured to activate the relay if the exit pushbutton is depressed Some software systems may allow configuration of this feature activate strike relay on exit pushbutton and others may not Strike _ Strike Power May Be Same As R...

Страница 37: ...ed The ADA 10 and ADA 11 relay module are designed for this purpose These relays are not included with the AAN 4 and must be purchased separately The purpose of the ADA 10 11 high security relay is to supervise protect the wiring between the reader and the electric strike IF THERE IS A POSSIBILITY OF AN INTRUDER ILLEGALLY GAINING ACCESS TO THESE WIRES THE ADA 10 11 SHOULD BE USED If someone illega...

Страница 38: ...Reader Detects the Door Contact Input Open Illegally Door Held Open Reader Detects the door has not closed after legal entry Auxiliary Alarm Either of the Auxiliary Alarm inputs are opened Reader Tamper AAN 4 Tamper Input is opened Because control of the local alarm relay is completely self contained within the reader interface this relay will activate anytime the above conditions occur regardless...

Страница 39: ...A 11 first the reader must be selected On the ADA 11 addresses are set by simply pushing the switch to the correct ON or OFF position on the device ADA 11 Reader Setting Reader S3 S4 1 OFF OFF 2 OFF ON 3 ON OFF 4 ON ON Table 3 6 1 ADA 11 Reader Setting Next the function of the ADA 11 must be defined For each group there are four possible settings ADA 11 Function Setting Function S1 S2 Strike Relay...

Страница 40: ... CUT 4 CUT CUT CUT NOT CUT Table 3 6 3 ADA 10 Reader Setting Next the function of the ADA 10 must be defined This is done by cutting one of the two function jumpers on the ADA 10 For each reader there are four possible settings ADA 10 Function Setting Function G1 G2 Strike Relay NOT CUT NOT CUT Local Alarm NOT CUT CUT Aux Relay 1 CUT NOT CUT Aux Relay 2 CUT CUT Table 3 6 4 ADA 10 Function Setting ...

Страница 41: ...st 3 7 1 Cabinet Tamper This is a normally closed input and should have a jumper installed if not used Cabinet Tamper Input TB19 This input is for connection to a switch located on the cabinet in which the AAN 4 is installed to detect unauthorized access to the panel This is a normally closed contact In the event of a tamper condition the exit push buttons will not function on all 4 reader connect...

Страница 42: ...Part Software Configuration Utilities IV ...

Страница 43: ... The InitAAN software utility the internal web pages or the internal Telnet server For ease of setup using InitAAN is recommended In addition to IP address programming additional security features can be enabled on the ENI 100 to protect from unauthorized use The default password is blank and should be changed on first use to prevent unauthorized configuration of the device This can be done throug...

Страница 44: ... function for this method Depending on the network devices that can be programmed may or may not be accessible using search a First enter the desired parameters For the ENI 100 only the IP Address can be configured using this utility all other parameters must be configured using the web page or Telnet For the ENI 1 Host IP Address Host Address Mask and Alternate Host IP address can be specified to...

Страница 45: ...40 Software Configuration Utilities 2011 Apollo Security Inc ...

Страница 46: ...figured using this utility all other parameters must be configured using the web page or Telnet For the ENI 1 Host IP Address Host Address Mask and Alternate Host IP address can be specified to restrict addresses that will be able to communicate with the ENI 1 d Confirm programming by accessing the device at the new address using a web browser or Telnet ENI 100 or using the Ping utility ENI 100 or...

Страница 47: ...address of your computer must be on the same network as the IP address of the ENI For the defaults in the ENI 100 IP Address 192 168 10 177 the computer s IP address would have to have the first 2 octets the same 192 168 x x for class B addresses and the first 3 octets 192 168 10 x for class C addresses To change the IP address first type the default address http 192 168 10 177 into the address fi...

Страница 48: ... of the devices type the desired address into the appropriate boxes Remember that the new IP address should be available from your network in able to be able to access this web page configuration screen again NOTE It is highly recommended that the default user name password should be changed on first use to secure the device from unauthorized use ...

Страница 49: ... ENI A screen will display to allow reset by clicking the Reset ENI button A status screen will be displayed while the ENI resets and when completed the ENI will use the new settings Note that if the IP address was changed it will be necessary to enter the new address in the browser address bar in order to access the web page configuration again ...

Страница 50: ...2 168 10 178 9999 This specifies to connect to address 192 168 10 178 on port 9999 Make sure to use the correct default address for your device and use a computer on the same network as the ENI NOTE Once a password has been specified for Telnet access the correct password must be entered within 5 seconds of opening the telnet session or the connection will be closed Passwords are case sensitive Up...

Страница 51: ...em 9 will exit the configuration and save changes Selection 8 exits the configuration without saving any changes keeping the previous settings SECURITY SETTINGS The following security settings can be changed only using the Telnet menu option 6 Security These options should be used to increase security of the ENI 100 by restricting changes to the configuration For options N No and Y Yes pressing EN...

Страница 52: ...figuration Key length in bits 128 See Encryption Configuration Enable Enhanced Password N Enable Disable 16 character password support If disabled the password length will only be 4 characters Disable Port 77F0h N Enable Disable advanced configuration port NOTE If Telnet Setup Web Server Setup and Port 77FEh are all disabled remote configuration will be completely disabled and no changes can be ma...

Страница 53: ...Part Troubleshooting V ...

Страница 54: ...cards is entered into the system but the Access Level assigned to the card does not allow access to the particular door at this time On readers with integral keypads the keypad may be verified by setting the reader into the Card and PIN mode After presenting a valid card the reader should flash the yellow LED if installed reader supports 3 color LEDs This indicates the reader is waiting for a Pin ...

Страница 55: ...Part Specifications VI ...

Страница 56: ...cations Relay Specifications Coil 12Vdc Contacts 2A 24Vdc 0 5A 125Vac Power Requirements 12 to 24Vdc 250mA Dimensions 7 5 in x 5 5 in 19 x 14 cm Environment Operating Temperature 0 to 50 C Storage Temperature 40 to 85 C Relative Humidity 0 to 95 non condensing ...

Страница 57: ...Part Supplemental Figures VII ...

Страница 58: ...53 AAN 4 Hardware Manual 2011 Apollo Security Inc 7 Supplemental Figures ...

Страница 59: ...54 Supplemental Figures 2011 Apollo Security Inc ...

Страница 60: ...55 AAN 4 Hardware Manual 2011 Apollo Security Inc ...

Страница 61: ...56 Supplemental Figures 2011 Apollo Security Inc ...

Страница 62: ...57 AAN 4 Hardware Manual 2011 Apollo Security Inc ...

Страница 63: ...58 Supplemental Figures 2011 Apollo Security Inc ...

Страница 64: ...59 AAN 4 Hardware Manual 2011 Apollo Security Inc ...

Страница 65: ...Part Table of Figures VIII ...

Страница 66: ...eader Input Wiring 25 3 6 Input Supervision 27 3 7 3 1 Strike Wiring Fail Secure 30 3 7 3 2 Strike Wiring Fail Safe 31 3 7 3 ADA 11 Loop and Strike Wiring 32 3 7 4 ADA 10 Hardware Layout 35 105 Signal Ground 53 113 Fault Caused by Incorrect AC Power Wiring 54 115 Ground Connection 55 116 Ground Fault Test Between Sub systems 56 117 Overview of Ground RS 485 Communication Wiring 57 120 Ground Check...

Страница 67: ...Part Revision History IX ...

Страница 68: ...al Release R Burnside A 1 23 MAR 2009 Update screenshot for ENI Config Part 3 2 R Burnside A 2 25 AUG 2010 Update ADA11 switch settings Add mounting holes diagram R Burnside A 2 1 19 OCT 2011 Update ADA 10 jumper settings Remove host limiting feature for ENI Higher resolution supplemental figures Correct 9 pin pinout for serial wiring diagram C Gray ...

Страница 69: ... G Gateway 22 Ground connections 17 Faults 17 18 Saftey Earth Ground 18 H Heartbeat 13 Host Communication Connection 18 Host List 22 I IP Address 22 38 Isolation Power 17 L LEDs 6 12 19 24 49 M Memory Backup 13 O On board memory 13 Operating Environment 51 P Power supply 17 R Routing 20 RS 232 19 RS 485 Device Drivers ASM 48 12 Signal Ground 17 S Self Test 12 Specifications 51 Start Up Mode 12 Sup...

Отзывы: