WARNING - To reduce the risk of injury or death:



READ AND FOLLOW ALL INSTRUCTIONS.



Installation should be performed by a professional installer.



Required welding should be performed by a qualified welder.



Should electricity be required, use a certified electrician only.



Any device that requires 120 Volts AC should be U.L. approved.



Ensure the gate and rollers meet U.L. standards.



All rollers should be covered to prevent injury. Install control devices such as keypads
far enough away (5 feet or further) from any moving parts of the operator and gate to
prevent possible injury.



A secondary entrapment device such as loop detectors, edge switches, and beam
detectors are highly recommended and required to meet the UL325 standard.



The “CAUTION AUTOMATIC GATE” signs should be clearly visible from both sides of
the gate.



Review with the owner all safety concerns including:



Do not operate the gate unless area around gate is in full view.



Never let children operate or play with gate controls. Keep the remote control
away from children.



Always keep people and objects away from the gate. NO ONE SHOULD CROSS
THE PATH OF THE MOVING GATE.



Test the gate operator monthly (see STEP 7 Programming the current sensitiv-
ity). The gate MUST reverse on contact with a rigid object or stop when an ob-
ject activates the non-contact sensors. After adjusting the force or limit of
travel, retest the gate operator. Failure to adjust and retest the gate operator
properly can increase the risk of injury or death.



Explain operation of the emergency release.



Always insure that the gate has closed securely before leaving area.



Arrange with local fire and law enforcement for emergency access.



Use the emergency release only when the gate is not moving.



Always disconnect the battery or power source when making adjustments or
repairs to any part of the gate or operator.



KEEP GATES PROPERLY MAINTAINED. Read the owner’s manual. Have a
qualified service person make repairs to gate hardware.



The entrance is for vehicles only. Pedestrians must use separate entrance.

SAVE THESE INSTRUCTIONS

IMPORTANT SAFETY INSTRUCTIONS

Содержание 7500ETL

Страница 1: ...Model 7300 INSTALLATION MANUAL APOLLO Gate Operators Inc Model 7500ETL Residential Heavy Duty Commercial Slide Gate Operator 08 18 09 Requires installation of 4 x4 mounting post not supplied...

Страница 2: ...5 Parts Identification 6 Post Installation 7 Operator Installation 8 Chain Chain Bolt Installation 9 Wiring Instructions 10 Internal Limit Adjustment 11 Quick Release Operation 12 Current Sense Adjust...

Страница 3: ...ldren operate or play with gate controls Keep the remote control away from children Always keep people and objects away from the gate NO ONE SHOULD CROSS THE PATH OF THE MOVING GATE Test the gate oper...

Страница 4: ...vent of power outages The battery may be recharged with a trickle charger or by solar energy Electrical battery chargers should have a class 2 transformer rating If a trickle charger is used and a sta...

Страница 5: ...mine the general location of the operator chain brackets and solar panel if used 1 Is there a suitable location for the operator 2 Can the solar panel if used be mounted in an unobstructed area facing...

Страница 6: ...0 Roller Chain 30 feet Master Chain Links 2 each Operator 5 16 Washers Lock Nuts Nuts 8 each 5 16 U Bolts 4 each Chain Bolts with hardware 2 each Base Plate Mounting Hardware 3 8 bolt 2 washers lock w...

Страница 7: ...gidity If you are not sure how deep to set the post contact a local fence installer for a recommendation 1 Position the gate closed 2 Check that there is at least two feet of gate or tail that is not...

Страница 8: ...level and parallel to the gate STEP 2 Bolt the main chassis on to the base plate using the four 3 8 bolts washers lock washers and nuts STEP 3 Assemble chain bracket with 5 16 U bolt hardware to each...

Страница 9: ...lt using the master chain link Do not tighten the chain bolts Note A chain breaking tool may be required to reduce the chain to the proper length STEP 3 Check chain align ment with idler sprockets Tig...

Страница 10: ...tor on the circuit board STEP 1 Determine which direction the gate will open The factory units are plugged into INPUT B for right hand opening as shown in Fig 1 For left hand opening disconnect from I...

Страница 11: ...uminated Limit adjustment for left movement gate moving to the left less travel more travel Limit adjustment for right movement gate moving to the right less travel more travel Step 4 Adjust the corre...

Страница 12: ...12 QUICK RELEASE OPERATION Engaged Engaged Pull handle out and lock by sliding to the right or left to disengage...

Страница 13: ...ould be set before beginning this procedure 1 Press and hold the LED ENABLE button for five seconds and release The STOP LED will blink indicating that the board is in learn mode 3 Cycle gate for 3 4...

Страница 14: ...Indicators Optional Device Input Remote Monitor Outputs and Photo Eye GateLink Connector Microprocessor Timer To Close Dual Gate Delay Current Sensitivity Adjustments Program Switches 835 836 Control...

Страница 15: ...835 836 board Connect the relay wires of the accessory as normal COM to GND NO to SAFETY 14 for a safety device When the gate operator begins opening comes off of the closed limits the MAS terminal wi...

Страница 16: ...eshooting Hold the push button down for five seconds to put the board in program mode RESET Resets the microprocessor Returns processor to last known state Jumpers STOP CIRCUIT JUMPER When the STOP CI...

Страница 17: ...utton released 6 LOCK TYPE For 12V mechanical solenoid locks For 12V magnetic locks 12V for 4 seconds on open cycle 12V when on close limit 7 COAST ENABLE Gate will stop immediately when at Gate will...

Страница 18: ...ion see program switch 5 for options OPEN Open input from a 3 button station see program switch 5 for options GND Supplied Battery Ground GND Supplied Battery Ground FREE EXIT Opens gate if closed sto...

Страница 19: ...or on the Remote Monitor Output Connector block Connect the black wire to the GND connector on the Remote Monitor Output Connector block Red Black Set Program Switch 4 as preferred ON Upon activation...

Страница 20: ...sition Transmitters must match code switches for proper operation If power is taken directly from battery or connected as shown below receiver should be configured for 12VDC Multi Code Digi Code Allst...

Страница 21: ...NGLE GATE 1 2 3 5 ON all others OFF DUAL GATE 1 2 5 ON all others OFF 3 LED ENABLE BUTTON On the right side of the board half way down is the LED ENABLE button Pressing this button once and releasing...

Страница 22: ...the wiring has been changed correctly Manually move the gate to the mid way position and plug the main harness into the EMERGENCY BYPASS receptacle the gate should OPEN If it closes the RED and BLACK...

Страница 23: ...lightning The manufacturer will not be responsible for any labor charges incurred in the removal or replacement of defective parts In case of failure due to defective material or workmanship during t...

Отзывы: