15
Board
Actuator
Function
Cable
Pin 1
Orange
Open Limit
Pin 2
White
Close Limit
Pin 3
Black
Motor (positive on open, negative on close)
Pin 4
Red
Motor (negative on open, positive on close)
Pin 5
Green
Common for both limit switches
Pin 6
Yellow
Feedback from intelligent actuator(816E/816EX)
Pin 7
Black
Battery Negative
Pin 8
Red
Battery Positive
1
3
5
7
2
4
6
8
Actuator Connector
Applies battery voltage directly to motor to open gate if
control board fails. User must unplug before gate opens
to maximum travel or 15 amp fuse will open. Fuse
should be checked before returning gate to service.
EMERGENCY BYPASS (open only)
Photo eye / safety loop wiring. Connect the positive power wire of the accessory to
12V. Connect the ground wire of the accessory to MAS (upper right area of the
835/836 board). Connect the relay wires of the accessory as normal: COM to GND.
NO to SAFETY (#14) (for a safety device). When the gate operator begins opening
(comes off of the closed limits) the MAS terminal will become a ground and will
complete the flow of power to the accessory. This will power the accessory up and it
will work as normal until the gate gets closed and the MAS terminal switches and the
device will power down.
Photo Eye Hookup
12V
Supplied battery voltage
MAS
Master Operator Indicator (indicates master side of gate is closed)
+12V when on closed limit. Ground when off of closed limit.
SLV
Slave Operator Indicator (indicates slave side of gate is closed)
+12V when on closed limit. Ground when off of closed limit.
GND
Battery supplied ground
SIREN
Connect to siren +
a12V when gate(s) are running, or in hard shutdown
GND
Battery supplied ground
LOCK
Connect to lock + (optional) Magnetic or Solenoid type locks (Dip Switch #6 Selectable)
Remote Outputs and Photo Eye Hookup