17
Program Switches
Setting shown are for
416E, 416EX, 7XXX
operators and 3500
operators.
OFF
ON
1 TIMER TO CLOSE
Gate does not automatically close.
Gate automatically closes.
2 TIMER TO CLOSE OPT.
Gate automatically closes from
Gate automatically closes only when completely
any position after opening.
open (open limit engaged).
3 SLAVE DISABLE
Enables slave side (dual gate use).
Disables slave side. (single gate use)
4 SIREN DELAY
Siren (optional) active when gate is
Siren (optional) starts 5 seconds before gate moves.
moving.
5 ‘STOP’ CIRCUIT ENABLE
Must hold down open or close
Normal operation
buttons to move gate. Gate stops
Momentary open or close input runs gate to limit.
when button released.
6 LOCK TYPE
For 12V mechanical (solenoid) locks.
For 12V magnetic locks.
(+12V for 4 seconds on open cycle)
(+12V when on close limit)
7 COAST ENABLE
Gate will brake when at Open or
Gate will coast (minimally) when it reaches limits.
Close limit
8 FREE EXIT OPT.
A free exit input will open gate from
A free exit input will open gate from any
closed position or after a close cycle
position after an open or close cycle.
only.
9 NOT USED
10 SMART ACT.
Off for 416E & 416EX actuators,
Used for 816E & 816EX actuators only
slide gates, 3500 or when slow down
(soft start & stop).
feature is not desired.