15
Board Actuator
Function
Cable
Pin 1
Orange
Open Limit
Pin 2
White
Close Limit
Pin 3
Black
Motor (positive on open, negative on close)
Pin 4
Red
Motor (negative on open, positive on close)
Pin 5
Green
Common for both limit switches
Pin 6
Yellow
Feedback from intelligent actuator (816E/816EX)
Pin 7
Black
Battery Negative
Pin 8
Red
Battery Positive
1
3
5
7
2
4
6
8
Actuator Connector
12V
Supplied battery voltage
SLV
Slave Operator Indicator (indicates slave side of gate is closed)
+12V when on closed limit. Ground when off of closed limit.
MAS
Master Operator Indicator (indicates master side of gate is closed)
+12V when on closed limit. Ground when off of closed limit.
GND
Battery supplied ground
SIREN
Connect to siren + (optional)
+12V when gate(s) are running, or in hard shutdown
GND
Battery supplied ground
LOCK
Connect to lock + (optional) Magnetic or Solenoid type locks (Dip Switch #6 Selectable)
Applies battery voltage directly to motor to open gate if
control board fails. User must unplug before gate opens
to maximum travel or 15 amp fuse will open. Fuse
should be checked before returning gate to service.
EMERGENCY BYPASS
Remote Outputs
Connects control board to a computer using
GateLink
software. This software
can monitor and diagnose the functions of the microprocessor. Ask your sales-
person about this feature.
GateLink
Connector