1
3
#14 AWG, 120V AC
#14 AWG, 240V AC
Length in Feet
5A
10A
15A
20A
Length in Feet
5A
10A
15A
20A
25'
0.6%
1.2%
1.8%
2.4%
25'
0.3%
0.6%
0.9%
1.2%
50'
1.2%
2.4%
3.6%
4.9%
50'
0.6%
1.2%
1.8%
2.4%
75'
1.8%
3.6%
5.5%
7.3%
75'
0.9%
1.8%
2.7%
3.6%
100'
2.4%
4.9%
7.3%
9.7%
100'
1.2%
2.4%
3.6%
4.9%
125'
3.0%
6.1%
9.1%
12.2%
125'
1.5%
3.0%
4.6%
6.1%
150'
3.6%
7.3%
10.9%
14.6%
150'
1.8%
3.6%
5.5%
7.3%
175'
4.3%
8.5%
12.8%
17.0%
175'
2.1%
4.3%
6.4%
8.5%
200'
4.9%
9.7%
14.6%
19.5%
200'
2.4%
4.9%
7.3%
9.7%
225'
5.5%
10.9%
16.4%
21.9%
225'
2.7%
5.5%
8.2%
10.9%
250'
6.1%
12.2%
18.2%
24.3%
250'
3.0%
6.1%
9.1%
12.2%
275'
6.7%
13.4%
20.1%
26.8%
275'
3.3%
6.7%
10.0%
13.4%
300'
7.3%
14.6%
21.9%
29.2%
300'
3.6%
7.3%
10.9%
14.6%
#12 AWG, 120V AC
#12 AWG, 240V AC
Length in Feet
5A
10A
15A
20A
Length in Feet
5A
10A
15A
20A
25'
0.4%
0.8%
1.1%
1.5%
25'
0.2%
0.4%
0.6%
0.8%
50'
0.8%
1.5%
2.3%
3.1%
50'
0.4%
0.8%
1.1%
1.5%
75'
1.1%
2.3%
3.4%
4.6%
75'
0.6%
1.1%
1.7%
2.3%
100'
1.5%
3.1%
4.6%
6.1%
100'
0.8%
1.5%
2.3%
3.1%
125'
1.9%
3.8%
5.7%
7.7%
125'
1.0%
1.9%
2.9%
3.8%
150'
2.3%
4.6%
6.9%
9.2%
150'
1.1%
2.3%
3.4%
4.6%
175'
2.7%
5.4%
8.0%
10.7%
175'
1.3%
2.7%
4.0%
5.4%
200'
3.1%
6.1%
9.2%
12.3%
200'
1.5%
3.1%
4.6%
6.1%
225'
3.4%
6.9%
10.3%
13.8%
225'
1.7%
3.4%
5.2%
6.9%
250'
3.8%
7.7%
11.5%
15.3%
250'
1.9%
3.8%
5.7%
7.7%
275'
4.2%
8.4%
12.6%
16.8%
275'
2.1%
4.2%
6.3%
8.4%
300'
4.6%
9.2%
13.8%
18.4%
300'
2.3%
4.6%
6.9%
9.2%
#10 AWG, 120V AC
#10 AWG, 240V AC
Length in Feet
5A
10A
15A
20A
Length in Feet
5A
10A
15A
20A
25'
0.2%
0.5%
0.7%
1.0%
25'
0.1%
0.2%
0.4%
0.5%
50'
0.5%
1.0%
1.4%
1.9%
50'
0.2%
0.5%
0.7%
1.0%
75'
0.7%
1.4%
2.2%
2.9%
75'
0.4%
0.7%
1.1%
1.4%
100'
1.0%
1.9%
2.9%
3.8%
100'
0.5%
1.0%
1.4%
1.9%
125'
1.2%
2.4%
3.6%
4.8%
125'
0.6%
1.2%
1.8%
2.4%
150'
1.4%
2.9%
4.3%
5.8%
150'
0.7%
1.4%
2.2%
2.9%
175'
1.7%
3.4%
5.0%
6.7%
175'
0.8%
1.7%
2.5%
3.4%
200'
1.9%
3.8%
5.8%
7.7%
200'
1.0%
1.9%
2.9%
3.8%
225'
2.2%
4.3%
6.5%
8.7%
225'
1.1%
2.2%
3.2%
4.3%
250'
2.4%
4.8%
7.2%
9.6%
250'
1.2%
2.4%
3.6%
4.8%
275'
2.6%
5.3%
7.9%
10.6%
275'
1.3%
2.6%
4.0%
5.3%
300'
2.9%
5.8%
8.7%
11.5%
300'
1.4%
2.9%
4.3%
5.8%
#8 AWG, 120V AC
#8 AWG, 240V AC
Length in Feet
5A
10A
15A
20A
Length in Feet
5A
10A
15A
20A
25'
0.2%
0.3%
0.5%
0.6%
25'
0.1%
0.2%
0.2%
0.3%
50'
0.3%
0.6%
0.9%
1.2%
50'
0.2%
0.3%
0.5%
0.6%
75'
0.5%
0.9%
1.4%
1.8%
75'
0.2%
0.5%
0.7%
0.9%
100'
0.6%
1.2%
1.8%
2.4%
100'
0.3%
0.6%
0.9%
1.2%
125'
0.8%
1.5%
2.3%
3.0%
125'
0.4%
0.8%
1.1%
1.5%
150'
0.9%
1.8%
2.7%
3.6%
150'
0.5%
0.9%
1.4%
1.8%
175'
1.1%
2.1%
3.2%
4.2%
175'
0.5%
1.1%
1.6%
2.1%
200'
1.2%
2.4%
3.6%
4.8%
200'
0.6%
1.2%
1.8%
2.4%
225'
1.4%
2.7%
4.1%
5.5%
225'
0.7%
1.4%
2.0%
2.7%
250'
1.5%
3.0%
4.5%
6.1%
250'
0.8%
1.5%
2.3%
3.0%
275'
1.7%
3.3%
5.0%
6.7%
275'
0.8%
1.7%
2.5%
3.3%
300'
1.8%
3.6%
5.5%
7.3%
300'
0.9%
1.8%
2.7%
3.6%
POWER CABLE VOLTAGE DROP (IN PERCENTAGE OF NOMINAL VOLTAGE)
Chart 3
Содержание APL-220
Страница 39: ...39 APL 220 SELF POWERED COMPACT SPEAKER Line Drawings ...
Страница 40: ...40 APL 500 SELF POWERED ARRAYABLE SPEAKER ...
Страница 41: ...41 APL 800 SELF POWERED ARRAYABLE SPEAKER ...
Страница 44: ...50 Spring Street Ramsey NJ 07446 USA Tel 201 934 8500 Fax 201 934 9832 www apogeesound com ...