VSD Pump - June 17
A. Insertion of the 5 connection wires cable pump:
-
Open the terminal box of the pump,
-
Remove the plug (on the side of the pump housing),
-
Screw the cable clamp onto the pump housing.
-
Place the connector on the card,
-
Pass the cable clamp, from the inside to the outside.
-
Tighten the «cable clamp» nut.
-
Close the housing.
Possible wiring at the end of the 5-wire cable :
GND = common = Black wire
By connecting : Black / Brown = speed 1
Black / Green = speed 2
Black / White = speed 3
Black / Red = Stop
B. Connecting the remote box *
- Open the housing,
- Pass the end of the cable into one of the wire cable,
- Connect the 5 wires of the cable in the housing (see diagram
below),
- Close the housing,
- Insert the transformer plug into the socket on the housing,
- Fix the housing at height,
- Connect the supplied power
supply of the remote unit to a 230 V
socket.
* Optional
Supplied with shunt
GND
V1
V2
V3
STOP
Noir
Marron
Vert
Blanc
Rouge
Black
Brown
Green
White
Red