APF VIPOOL MJB VSD Скачать руководство пользователя страница 14

14

VSD Pump - June 17

7. CAUTIONS ON OPERATING THE PUMP

▪ The pump should operate without making any noise or vibrations. 
▪ Check for any leaks on a regular basis. 
▪ Clean the prefilter basket on a regular basis. 
▪ Always stop the pump before handling the valve on your filter (6-way) on the 

swimming pool’s hydraulic circuit. 
▪ This electrical pool pump is fitted as standard with a flexible filter bag inserted 

in the pre-filter basket. This is intended to trap fine impurities (gravel, sand, pine 

needles,  etc.)  which  can  often  prevent  pumps  from  operating  correctly.  When 

using the pump for the first time, when there is sand or pine needles present in 

the pool, or if a manual broom has been used, these are situations where the use 

of the flexible filter bag is essential. We therefore advise you to leave this option 

permanently in position and, of course, to check and clean it regularly (at least once a week). 

If the electrical pump is returned to us for after-sales service due to a blockage of the turbine from impurities larger 

than the flexible filter bag’s straining capability, the item will not be repaired under warranty. 
You can obtain additional flexible filter bags from your usual supplier.

Risk of injury to persons without the required qualifications. Repair and maintenance work must be carried 

out by specially trained personnel. 
▪ When working on the pump : 
- Cut off the electricity supply 
- Make sure the switch is set to “off” 
- Wait for the motor to have come to a complete stop. 
▪ The mechanical seal is a vital component of the pump. It should be replaced with the utmost care. It is 

advisable to contact a specialist for this task. 
▪ Disassembly/Re-assembly: Take the necessary precautions to avoid trapping your hands or feet. 
- Clean and check all parts before reassembling them. 
- Replace all worn or damaged parts (imperative). 
- Make sure the seals are clean and in the correct position. We recommend you only reposition new seals. 
▪ In all spare part orders, please specify: the type of pump (data plate), the pump’s serial number (data 

plate), the part’s position number (exploded view), the name of the part (table and exploded view). 

9. HIVERNAGE

9. WINTERING

▪ The pump must be emptied out through the plughole for anti-freezing 
purposes. 

 

Prefilter basket

Flexible pocket filter

®

8. INTERVENTION ON THE PUMP

Содержание VIPOOL MJB VSD

Страница 1: ...INFORMATION SETTINGS swimming pool pump MJB VSD...

Страница 2: ...aulic connections P 5 3 B Electrical connections P 5 4 Control of the pump P 5 5 Operating of pump terminal box P 7 6 Operating of the remote box option P 10 6 B Additionnal functions THG et OME P 12...

Страница 3: ...Visual control keypad with 5 colored keys 3 keys setting of the programmed speeds 2000 2400 and 2850 rpm pre Recorded and modulable from 1000 to 2850 rpm 1 key on and off 1 key to access the menu Time...

Страница 4: ...t of a malfunction or failure please contact your nearest manufacturer s representative or the manufacturer s Technical Support Service Hot surface in the area around the motor This document contains...

Страница 5: ...nnected so as to avoid the pump and pipe from being subjected to external stresses which could cause them to break irrespective of the assembly operations We recommend a vertical pipe length of approx...

Страница 6: ...re cable GND common Black wire By connecting Black Brown speed 1 Black Green speed 2 Black White speed 3 Black Red Stop B Connecting the remote box Open the housing Pass the end of the cable into one...

Страница 7: ...table priming time 0 to 10 minutes by 1 minute steps B User interface A Led screen displays the engine speed B SET key accesses the programming mode or resets the command C 1 key selects the fixed spe...

Страница 8: ...ing step To stop the motor press the 0 key The Power LED flashes and the screen shows OFF Notice When the MJB VSD is used with the remote control unit the connection to the control unit must be shut d...

Страница 9: ...d set between 0 off and 10 minutes priming F Reset To restore the factory settings to the motor hold down the SET button for about 15 seconds The motor stops and the three fixed speed LEDs light up Th...

Страница 10: ...the program see next section Return Vary with the touchpad arrows Input screen in the program Select program 1 or 2 for settings Choose the arrows and press OK for validation Screens for choosing dail...

Страница 11: ...shows day and hourly programmed speeds 0 to 12 hours and 12 to 24 hours per 1 hour interval in 1 hour O Off no filtration Speed 1 Speed 2 Speed 3 Programming speeds according to the hours on a weekly...

Страница 12: ...set on the THG This allows the pump to start in V1 so as to prevent from freezing To do this rotate the scroll wheel to the position Lack of water option This option is composed of a 50 x 1 1 2 suppor...

Страница 13: ...e event of an error the motor stops permanently Exception error Undervoltage insufficient voltage The motor restarts automatically as soon as the voltage becomes greater than 209 V for at least 6 seco...

Страница 14: ...er bag s straining capability the item will not be repaired under warranty You can obtain additional flexible filter bags from your usual supplier Risk of injury to persons without the required qualif...

Страница 15: ...tion direction three phase motor Check the condition of the couplings and seals along the suction pipe Invert 2 phases on the electricity supply Weak pump output Pressure loss in the suction Check the...

Страница 16: ......

Отзывы: