![APEXi Super AVC-R Скачать руководство пользователя страница 8](http://html1.mh-extra.com/html/apexi/super-avc-r/super-avc-r_instruction-manual_2953208008.webp)
*Our company can provide the proper upgrade injectors.
BCNR33/BNR32/RNN 14 ... , .... 550cc/min: Y20000/pc
(Part
I)
ECRJJ/S 14/#PS IJ ..
.
.
..
..
.
�
.
.
.
. . . .
44-occ/min:Y24000/pc - --
(Part number:404-N002)
IMPORT ANT ( Same for actuator and wastegate
type)
•
Changes in either the preset boost pressure or duty level will reset the self learning runction.
(Even if the boost pressure was changed and then returned to its previous setting)
•
As
long as the basic requirements are fulfilled, the self learning function will automatically
proceed under normal dnving conditions. Please follow the steps below to speed up the self
learning function process.
I. Drive the vehicle in as high of a gear as possible in order to get the boost pressure to match the
specified boost level at the lowest possible RPM. ( the intercept RPM) ( Running the vehicle from
the intercept RPM+ 1000 RPM is acceptable.)
2. Neitt, run the vehicle in the mid and high RPM of a mid-range
gear to match the specified
boost level.
3.
Repeating steps I and 2 will speed up the self learning function.
4. If the boost pressure does not rise properly, please reset the self learning function or check the
set boost pressure again.
•
Be sure to reset the duty level and repeat the programming sequence from the beginning when
modifying either the actuator or wastegate.
4.
Set Up Loci< F1111ctio11
This lbnction allows the user to lock the fu11ctio11s accessible on the front part of the unit.
(The steps
1-3
when setting the presets in the set up mode)This safety feature has been designed
to prevent the self leaming function from being reset by accident, prevent others from modifying
the boost pressures and damaging the engine, and to prevent all other potential trouble.
I. While the unit is ON, press both the SEL ECT a11d the Up switch immediately.
2. The display will change from the normal screen to unL-000. This unL-000 denotes the lock
function has been released.
..
displays the unlocked situation
displays the unlock code
3.
Set the unlock code by pressing either UP or D OWN. ( 000-999)
(We recommend writing down the unlock code on a separate sheet of paper for reference.)
4. Set the desired lock code by pressing the MODE switch. The display will read Loe at this time
and return to the monitor mode.
..
EX:
if the lock code is 890
Begin the setup lock
-11-
5. Follow the
same
procedures to unlock the unit.
6. When following step I now, the screen will read Loc-000 showing that the unit is locked.
7. Enter the set lock code by using the UP/D OWN button and press the MODE button. lf the
correct code has been entered, the display will read unL and release the lock.
IMPORTANT* Plense stnrt nt step
6
if the wrong code hns been entered. Jf the lock code
hns beeu lost or forgotten, disco1111ecting the connector or the bnttery will relense the
locking function. This procedure however, will ernse nil recorded dntn so plense slnrt the
llrogrnmmiug 1wocess frem
the
bcgi1111i11g.
[2J Mo11itor Mode
l.
Boost Pressure Displny Function
This unit displays the absolute pressure of 760 mmMg as 0 kg/cm2 and engine boost ns
kg/cm2. Also the unit reads the absolute pressure of760 mmHg as Omm.Hg and the engine
vacuum as minus mmHg.
2.lnjector Pulse Dis1>lny Function
The injector pulse display limction of this unit reads the ma:ii:imum injector capacity as I 00% and
displays the % of injection from that point. The display will begin to flash if the injectors reach
over 98% capacity.
!CAUTION Some vehicles mny eipericuce a scattered injector reading under full lond
because this unit uses the injector signnl fo1· its h1jector pnlse displny. Vehicles equipfled
with 1111 clectl'icnl cnrrcnt controller for its injecton cannot use this fu1ictio11. ( PZ31, RJI
etc
•..
)
I. While the ignition key is ON, whether the unit is turned OFF or ON, the display feature will
function for both the digital display and bar graph.
2. Since the boost pressure display and injector pulse display is accompanied by the digital and bar
graphs, toggling between the two displays is possible. The display limits for boost pressure is -760
mmHg-2.00 kg/cm2, and 0 - I 00% for iltjector pulse. The bar gra1>h reads 0.60-1.50 kg/cm2 and
10-100% respectively within the 10 LED's displnying increments ors units .
3.
Use the MODE switch to toggle between the various displays. For instance, if the present
display shows boost display in digital form, the bar graph will denote the injector pulse. Pressing
the MODE button again will switch again to the other display .
EX: The present display shows boost at 1.60 kg/cm2 and the injector pulse at 98%in bar and
digital form.
- 12