The GlucoSure STAR Blood Glucose Test Strip

The GlucoSure STAR Test Strips are glucose specific, biosensor-based test

strips that can test glucose in capillary whole blood in as quickly as 6 seconds

and requires very little blood sample. The test result is plasma referenced for

easy comparison to lab results and has under-fill detection to alert you when

there is not enough blood to perform a test, so you can be assure that each read-

ing you get is an accurate and meaningful result.

IMPORTANT:

• Be sure to use only the GlucoSure STAR Blood Glucose Test Strip with the

GlucoSure STAR Blood Glucose Meter. Other brands of test strips will not

work with the Meter.

• The GlucoSure STAR Blood Glucose Test Strips are sensitive to moisture

and light, it is important to close the vial cap of the test strip bottle tightly

after each use. DO NOT leave any test strips outside the bottle while not in

use.

• Carefully discard used test strips and lancets in proper waste containers.

ST

AR

10

U

nd

ers

ta

nd

in

g

Y

o

ur

N

ew

B

lo

o

d

G

lu

co

se

K

it

Contact Points

Insert this end to the Test

Strip Port on the Meter.

Sampling End

Apply blood or con-

trol solution here

Содержание GlucoSure STAR

Страница 1: ...ead it carefully Your GlucoSure STAR Blood Glucose Monitoring System provides an easy and precise way to measure blood glucose using fresh capillary whole blood taken from fingertips palm or forearm T...

Страница 2: ...een 7 The GlucoSure STAR Blood Glucose Test Strip 10 Setting Up Your New System EInserting or Changing the Battery 11 ECoding the Meter 13 ESetting the Clock 15 ETurning ON OFF Beep Sound 20 Control S...

Страница 3: ...Blood Glucose Test 35 Understanding Your Blood Glucose Test Results 41 Viewing Stored Readings and 7 14 30 Days Average from Memory 43 Caring for the Meter Cleaning the Meter 47 Storage and Precaution...

Страница 4: ...luded in some areas STAR 4 Understanding Your New Blood Glucose Kit MENU ENTER Blood Glucose Meter N s u s G A M u G 0800 050100 e mail info apexbio com w ww CONTREX PLUS A G1 Y t 2 Y t T N LOT G EXP...

Страница 5: ...or Setup or exit and return to testing when viewing meter memory or setup Test Strip Port This is where you insert the test strip and the Meter will turn on automatically Scroll Buttons Press for scro...

Страница 6: ...r New Blood Glucose Kit Battery Compartment Holds two 1 5V AAA batteries Code Card Port Insert the code chip see page 13 here Ejection Switch Push and eject a used test strip see page 10 Meter will be...

Страница 7: ...Meter Display Screen STAR 7 Understanding Your New Blood Glucose Kit HAPPY SAD FACE BEEPER CODE TEMPERA TURE TEST STRIP MONTH DAY DAY AVG MINUTES HOUR MINUTES BLOOD DROP and ARROW UNITS MAIN DIS PLAY...

Страница 8: ...or too cold to test outside the ranges of 10 C 40 C 50 F 104 F TEST STRIP This icon will flash to prompt you to insert a test strip for testing CTL This icon indicates a control solution test see pag...

Страница 9: ...e display area is a stored test value see page 43 UNITS Unit of measurement for your blood glucose DISPLAY AREA Displays code number test results stored test val ues calculated result averages and mes...

Страница 10: ...meaningful result IMPORTANT Be sure to use only the GlucoSure STAR Blood Glucose Test Strip with the GlucoSure STAR Blood Glucose Meter Other brands of test strips will not work with the Meter The Glu...

Страница 11: ...d Two Alkaline AAA Batteries Supplied in Kit Your GlucoSure STAR Meter Step 1 Press firmly on the battery cover and slide in the direction of the arrow to open the cover Step 2 Insert new batteries ac...

Страница 12: ...ither by a Test Strip or pressing If it is correct press again to exit or if the time and date are not correct see page 15 for Setting the Clock The date code number and stored results will not be era...

Страница 13: ...Blood Glucose Test Strip Your GlucoSure STAR meter Step 1 Insert the code card with the connectors facing up Make sure it is completely Inserted into the code card port Step 2 Take out a GlucoSure ST...

Страница 14: ...while the meter is turned on The display screen will flash and show the new code number from the code card Make sure the numbers from the meter display screen the code card and the test strip package...

Страница 15: ...s of self tests will appear on the screen when all tests are complete If or other error messages Err 1 Err 2 etc appears see Solving Problems on page 49 Step 3 After the 4 digit code number and a flas...

Страница 16: ...orrect year Press the button to confirm your choice and to advance to set the month Set month Step 5 The current month will flash Use the or buttons to select the correct month Press the to confirm yo...

Страница 17: ...ay Press the button to confirm your choice and to advance to set the hour Set Hour Step 7 The current hour will flash Use the or buttons to select the correct hour Press the button to confirm your cho...

Страница 18: ...r choice and ad vance into setting 12 hours or 24 hours time format Set Time Format to 12 hours or 24 hours Step 9 The current time format will flash Use or buttons to se lect either 12 hours format o...

Страница 19: ...Test Strip and begin testing The changes you have done so far will be memorized by the meter Begin testing see page 30 Testing Your Blood Glucose or press and hold to turn off the meter or see the nex...

Страница 20: ...rtant cues from your Meter such as confirmation or error messages Step 1 Press the button to confirm your choice and to advance to turning the beeper on or off Step 2 Use the Scroll Up or the Scroll D...

Страница 21: ...ing The changes you have done so far will be memorized by the Meter Begin testing by inserting a GlucoSure STAR Blood Glucose Test Strip see page 30 Testing Your Blood Glucose or press to return to th...

Страница 22: ...lus Level 1 Glucose Control Solution to check the system performance at low glucose concentrations You should perform control solution testing when Using the Meter for the first time You open a new bo...

Страница 23: ...on three months after opening DO NOT FREEZE Store the control solutions at room temperature 15 C 30 C 59 F 86 F Materials you will need Contrex Plus Control Solution Level 1 or Level 2 Your GlucoSure...

Страница 24: ...e opened on the test strip bottle label when you first open it 3 months after first opened date discard the bottle and any remaining Test Strip Make sure you are testing in an environment that is betw...

Страница 25: ...should be the same IMPORTANT Always match the code number displayed on screen to the code number printed on the test strip bottle The code number on the test strip bottle and on the display must be t...

Страница 26: ...icate that the Meter is in Control Solution Testing If you decide not to do a control solution test press twice to remove ctl from the meter display Step 4 Squeeze a drop of Contrex Plus Level 1 Contr...

Страница 27: ...display count down bars that will gradually di minish After 6 seconds the control solution testing result will appear on the meter display screen Step 7 Compare the reading on the screen to the Level...

Страница 28: ...o proper waste basket by either using the ejection button on the Meter or remove by hand The meter will automatically shut off after the Test Strip has been ejected or removed or will shut off after 2...

Страница 29: ...the Meter Meter malfunction Control solution not at room temperature Make sure you are using Contrex Plus Con trol Solution Level 1 or Level 2 Make sure the testing environment is between 10 C to 40...

Страница 30: ...st See Setting Up Your New System on page11 and Control Solution Testing on page 22 for de tails Wash your hands and testing site thoroughly with soap plus warm water and dry well You are testing in a...

Страница 31: ...wn firmly until it is fully seated Step 2 Twist the protective cover off from the lancet Twist clockwise the adjustable cover back onto the lancing device Note For fingertip testing use the blue adjus...

Страница 32: ...le cap pull back the lancing device with your other hand until you hear a click sound The lancing device is now ready for blood sampling IMPORTANT Use a new sterile lancet every time you test to avoid...

Страница 33: ...s between your fingertip and palm and forearm 1 alternate site test result maybe significantly different then results from fingertip testing under certain conditions You should consult with your docto...

Страница 34: ...testing do not agree with how you feel use finger tip testing instead 1 Jungheim K Koschinsky T Risky delay of hypoglycemia detection by glucose monitoring at the arm Diabetes Care 2001 24 7 1303 04...

Страница 35: ...the test strip bottle and its package Do not use expired test strips Use each test strip immediately after removing it from the bottle Do not use wet or damaged test strips Keep away from direct sunl...

Страница 36: ...reen IMPORTANT Replace the code card if code number displayed on screen and the code num ber printed on the test strip bottle do not match refer to Coding the Meter on page 13 Remember to change the c...

Страница 37: ...button to create a puncture TIP Gently message your hand and finger toward the puncture site to form a drop of blood approximately Do not milk or squeeze around the puncture site Lance the side of yo...

Страница 38: ...t up For forearm test sites apply and release pressure Pumping for a few seconds while keeping the lancing device in constant contact with the skin Palm testing at the base of the thumb does not requi...

Страница 39: ...bars that will gradually di minish After 6 seconds your glucose testing result will appear on the meter display screen Your test result will be automati cally stored into the meter memory CAUTION If y...

Страница 40: ...tically shut off Step 7 Remove the used lancet from your lancing device according to instructions and discard into proper wastebasket IMPORTANT Discard used test strips and lancets according to your l...

Страница 41: ...ter meal 1 It is important to consult with your physician or healthcare professional to de termine an appropriate target range for you What to do if you get a high or low reading If the Meter displays...

Страница 42: ...bottle Repeat your test Test your Meter with a Control Solution refer to page 22 Control Solution Testing If you still get a high or low reading contact your health care professional Reference 1 Sted...

Страница 43: ...track your effort in controlling your blood glucose level You will need to set your meter date and time to use the mem ory and day averaging function see Setting Up Your New System on page 15 The mete...

Страница 44: ...isplay screen along with your most recent blood glucose testing or control testing result Press to see the next result Keep on pressing the to view older results one by one or hold it down to scroll t...

Страница 45: ...rage is displayed you can press to go back viewing your averages and stored readings Note Control testing results will be flagged by a ctl icon on the bottom left corner of the display screen in addit...

Страница 46: ...cause the oldest one to be deleted Memorized test results and day averages will not be erased when changing batteries After finish viewing memory or days averages either begin testing by inserting a G...

Страница 47: ...a mild detergent Do not get water inside the GlucoSure STAR Meter Never immerse the meter or hold it under running water Do not use glass or household cleaners on the meter Do not try to clean the tes...

Страница 48: ...r removing a test strip and make sure it s closed tightly Do not take the meter apart Doing so will void the warranty Do not use this meter in a dry environment especially if synthetic materials are p...

Страница 49: ...ired Check the test strip bottle and verify the expiration date Check the Code Number on both the Meter display screen and the test strip bottle or its package to make sure they match Check if Meter s...

Страница 50: ...st Strip Not enough sam ple in the Test Strip to start Remove the Test Strip and repeat the test with a new Test Strip See Testing Your Blood Glucose on page 30 The Meter is damaged Remove the battery...

Страница 51: ...r it to reach the new temperature Test result is higher than 600 mg dL 33 3 mmol L Wash and dry your hands and repeat the test using a new Test Strip If the result is still HI contact your physician o...

Страница 52: ...ange the battery according to page 11 Inserting or changing the Battery There are no mem orized results in the Meter Check if the date and time on you Meter is set up See Setting Up Your New System on...

Страница 53: ...and in no event shall Apex Biotechnology Corporation be liable for any collateral or consequential damages or loss Instruments subjected to misuse abuse neglect unauthorized repair or modifi cation wi...

Страница 54: ...e Large LCD screen Memory 300 blood test results with date and time Result Averaging 7 14 and 30 days averaging Dimension 90L x 53W x 20H mm Weight 80g Battery 2 Alkaline AAA Battery Battery Life 1000...

Страница 55: ...on according to IEC EN 60601 1 IPXO not evaluated as AP APG equipment continuous operation Electromagnetic Compatibility This equipment complies with EMC re quirement of EN 60601 1 2 EU directive clas...

Страница 56: ...mperature limitations Consult instructions for use In vitro diagnostic device Caution warning consult accompanying documents Product code number Keep away from sunlight direct light Do not re use Manu...

Страница 57: ...GlucoSure Star Kit mg dL S70008 GlucoSure Star Basic mmol L S70009 GlucoSure Star Kit mmol L S5636026 GlucoSure Star 25 s Test Strip mg dL S5636053 GlucoSure Star 50 s Test Strip mg dL S5636052 GlucoS...

Отзывы: