25
-
Switch off the boiler heating switch.
-
Continue working to use up any remaining steam in the boiler. If this is not done, you
will not be able to
o
pen the self-locking
filler
cap.
-
Switch off the main switch.
-
R
emov
e the
plug from a s
o
cket.
-
With a towel to protect your hand carefully unscrew the self-locking cap and let any
remaining steam escape
-
Remove the safety cap.
-
Fill the tank with water as described
in section
“Setting up/How to fill the
boiler
”(page
-
9
).
-
Re-connect the appliance and start up as described
in section
“How to start up” (page
-
10
).
DESCALING
(Fig. 14)
(every 3-4
weeks)
ATTENTION:
Never descale
the appliance
when still
warm.
-
Unplug.
-
Fill the tank with tap water.
Do not add
anything other
than simple tap water
-
Hold the appliance
upright and shake
thoroughly
to loosen any
scale in the boiler chamber.
-
Open the drain at the bottom of the boiler (
14
) using the key on the safety cap.
-
Collect the water coming from the
boiler
.
-
Rinse the repeatedly with tap water (
ONLY TAP WATER
) until
t
here are no
further traces of scaling.
-
Close the drain at the bottom of the boiler (
14
).
CLEANING THE APPLIANCE
Clean the appliance and accessories with a damp cloth. Never use steam or immerse in
water.
MAINTENANCE
REFILLING THE WATER TANK
DURING OPERATION
Fig. 14
An indicator light will tell you when there is no more water in the cleaner (E-fig.2)
If this happens the boiler stops heating automatically.
WHAT TO DO
Содержание APX390
Страница 2: ......
Страница 40: ...40 Cod Q69103599 rev 0 11 2016...