Rack mounting
The PE232MKII is designed for standard 19” rack mounting as well
as free standing outside a rack cabinet. The unit requires three
standard rack units.
Mounting the unit directly over large heat-producing devices may
shorten component life and therefore, is not recommended.
Ambient temperature should not exceed 50 degrees Celsius when
the equipment is powered.
Because of the chassis’ mechanical construction, the PE232MKII
has no need for support at the rear when mounted in a rack
cabinet. This feature facilitates manipulation of the unit while
ensuring perfect mechanical stability.
Make sure there is enough room for air circulation between
different pieces of equipment and through the heatsink at the back
14
4 SERIAL NUMBER
This number is the fingerprint of the unit and should be quoted in
any correspondence concerning the unit.
5 SIGNAL GROUND LIFT
This switch disconnects the signal ground from the mains and
chassis earth. The switch should be used if hum due to ground
loops is experienced and will generally solve the problem.
6,8 Balanced IN A/B
Connects the equaliser to balanced outputs. The connector is a
female Neutric XLR NC3FD. For wiring details see section 'Signal
connections'.
7,9 Balanced OUT A/B
Connects the equaliser to balanced inputs.The connector is a male