Type number coding of the INVONIC H heat/cooling meter:
A B C D E F G H I J
Communication modules
Code
none
A
M-Bus module
B
current loop (CL) module
C
radio wM-Bus S1 module (868 MHz)
D
Modbus RTU RS-485 module
E
radio wM-Bus T1 OMS module (868 MHz), individual password per module
F
radio wM-Bus T1 OMS module (868 MHz), common password for all
modules
G
BACnet MS/TP RS-485 module
H
Flow sensor to calculator wiring length
Code
1.2 m
1
2.5 m
2
5.0 m
5
Configuration profiles settings applies only to wM-Bus radio module
(in the case of other modules default profile name is "A")
Code
walk-by system: radio module transmits the following registers every 30 s,
from Monday to Friday, from 6 to 18 (6 AM to 6 PM): serial number; date;
heat energy; cooling energy**; volume; actual flow and power; volume from
pulse input 1 and 2; energy and volume of last month with write date;
energy
and volume of last year with write date; active errors with timestamp;
operating time without energy calculation error; supply and return
temperature
A
drive-by system: radio module transmits the following registers every 20 s,
from Monday to Friday, from 6 to 16 (6 AM to 4 PM): serial number; date;
heat energy; cooling energy**; volume; volume from pulse input 1 and 2;
energy and volume of last month with write date;
energy and volume of last
year with write date; active errors with timestamp
B
stationary system: radio module transmits the following registers every 180
s, 24/7: serial number; date; heat energy; cooling energy**; volume; actual
flow and power; volume from pulse input 1 and 2; energy and volume of last
month with write date;
energy and volume of last year with write date; active
errors with timestamp; operating time without energy calculation error; supply
and return temperature; maximum temperatures, flow and power during last
month
C
Temperature sensors
Code
none (without bolt protecting temperature sensor sleeve in the meter body)
0
none (with bolt protecting temperature sensor sleeve in the meter body)
1
pair of Pt500 M10x1 sensors for direct installation with 1.5 m long wiring
and a brass fixing screw (Ø 5.2 mm, 0-150°C)
2
pair of Pt500 M10x1 sensors for direct installation with 1.5 m long wiring
and a plastic fixing screw (Ø 5.2 mm, 0-150°C)
3
pair of Pt500 M10x1 sensors for direct installation with 2 m long wiring and
a plastic fixing screw (Ø 5.2 mm, 0-150°C)
4
pair of Pt500 M10x1 sensors for direct installation with 2 m long wiring and
a brass fixing screw (Ø 5.2 mm, 0-150°C)
5
pair of Pt500 M10x1 sensors for direct installation with 3 m long wiring and
a plastic fixing screw (Ø 5.2 mm, 0-150°C)
6
pair of Pt500 M10x1 sensors for direct installation with 3 m long wiring and
a brass fixing screw (Ø 5.2 mm, 0-150°C)
7
pair of Pt500 M10x1 sensors for direct installation with 5 m long wiring and
a plastic fixing screw (Ø 5.2 mm, 0-150°C)
8
pair of Pt500 M10x1 sensors for direct installation with 5 m long wiring and
a brass fixing screw (Ø 5.2 mm, 0-150°C)
9
pair of Pt500 sensors for installation in pockets with 3 m long wiring (Ø 6
mm, 0-150°C)
A
pair of Pt500 sensors for installation in pockets with 5 m long wiring (Ø 6
mm, 0-150°C)
B
* with the exception of flow sensors with a nominal flow q
p
0.6 m
3
/h; 1 m
3
/h; 1.5 m
3
/h (130 mm); 3.5 m
3
/h
** register available only in heat and cooling meters