No.
Parameter
Display indication**
Parameter notes
3.10*
Day of monthly data writing
When set to "31", the data saving will be done in the last
calendar day of the month.
3.11*
Tariff 1 settings
Tariff 1 when:
T1-T2 < 10.0°C
or >10.0°C
or from 10.0 to 40.0°C
(changes every 1 s)
or a time interval in hours
(00-24h)
or the tariff is activated
directly by pulse input:
It is possible to choose: one of the measured parameters,
1
st
or 2
nd
pulse input (if pulse inputs are enabled), one of
the temperature (supply or return) or temperature
difference.
3.12*
Tariff 2 settings
As in menu 3.11; only "L1"
change to "L2"
See parameter 3.11 notes.
3.13*
1
st
pulse input/output configuration
Input:
input (tariff activation):
Output:
energy or volume of
working medium
Tariff
Tariff status:
Input: configurable for water volume indication only.
Minimum pulse indication resolution: 0.00001 m
3
.
Output: configurable for working medium volume (m
3
),
heat energy (as shown on the example), cooling energy
(displayed with the snowflake symbol
), or to one of the
tariffs.
3.14*
2
nd
pulse input/output configuration
As in menu 3.13; only "1"
change to "2" in the top
left corner of LCD
See parameter 3.13 notes.