CRS 40 V2
Installation, operation and service manual
M2019/02a
10. D
ESCRIPTION
OF
THE
GRAPHICAL
INTERFACE
10.1. C
ONNECTING
TO
THE
READING
NETWORK
Open a web browser, such as Google Chrome, Mozilla Firefox, Internet Explorer, etc. The list of browsers for
which the software is tested can be found in the chapter Error: link source not found Error: link source not
found. If some browser or an older version is used, some features may be unavailable. Enter the IP address
of the reader network control unit B that you want to connect to in the address bar. The IP address can be
found on the identification label of the unit (Illustration 6: I Identification label of the unit B). Do not forget to
check that you have a VPN attached (see chapter 9. Connection to reading network ).
10.2. L
OGGING
IN
TO
THE
READING
NETWORK
After connecting to the reading network, the log in page opens first. For first login, the login name “ admincrs”
and password "159753 " (without quotation marks) are set by default. Once you've first logged in, change the
data in Settings (Access Set Up for Readout Administration).
If you forget your login information, you can send it to the e-mail you entered in <Settings> in the <E-mail
address for error messages> box.
10.3. M
AIN
PAGE
OF
THE
READING
NETWORK
After a successful login, the main page of the reading network opens. On this page you will find the main
readout data by date (in yyyy-dd-dd format):
•
Missing / Unread / Total
- the read-out device is considered to be Missing if it does not occur after a
set period of time (default 7 days, more in Chapter 10.5 Setting System Parameters) to receive data
from this unit. This may be due to a failure, dismounting, or shielding by material impenetrable for
radio waves. A device is assigned as Missing if it has not been deducted by the system for at least 1
day but shorter than the set time. The rationale for classifying a unit between an unrecorded one
may be only a temporary deterioration of the radio broadcasting conditions, so the system is not
considered to be an error (no error message is sent). Clicking on a specific item opens a detailed list
of non-found or unread units.
•
The electronic seal violation
- if the heat cost allocator from the radiator or radio module is
removed from the water meter, or if the long-term presence of the magnetic field is detected near the
radio module, the unit sends the radio signal in the radio signal. The module indicates magnetic field
detection only after the presence exceeds several hours. The time at which the presence of the
40 / 57