background image

Installation

 

instructions:

  

You

 

must

 

assign

 

the

 

ZONE4R

 

unit

 

to

 

a

 

zone

 

number

 

by

 

pushing

 

knob

 

‘1’

 

and

 

‘3’

 

simultaneously

 

during

 

5

 

seconds.

 

The

 

selected

 

zone

 

number

 

is

 

displayed

 

on

 

the

 

screen

 

‘2’.

 

To

 

change

 

the

 

zone

 

number,

 

push

 

the

 

up

 

or

 

down

 

switches

 

‘5’

 

or

 

‘6’.

 

After

 

a

 

few

 

seconds,

 

the

 

ZONE4R

 

returns

 

to

 

normal

 

operation

 

and

 

will

 

memorize

 

its

 

assigned

 

zone

 

automatically.

 

You

 

can

 

also

 

switch

 

zones

 

by

 

pushing

 

the

 

small

 

switch

 

at

 

the

 

back

 

of

 

the

 

unit.

 

With

 

every

 

push,

 

the

 

zone

 

number

 

changes

 

1

 

up,

 

from

 

1

 

to

 

4

 

and

 

back

 

to

 

1

 

and

 

so

 

on.

 

You

 

can

 

connect

 

multiple

 

ZONE4R

 

units

 

to

 

the

 

ZONE4

 

main

 

unit

 

using

 

a

 

straight

 

through

 

CAT5

 

cable

 

hub.

 

You

 

can

 

assign

 

multiple

 

ZONE4R

 

units

 

to

 

the

 

same

 

zone.

        

The

 

maximum

 

number

 

of

 

ZONE4R

 

units

 

connected

 

to

 

a

 

single

 

ZONE4

 

unit

 

is

 

8

 

pieces.

 

Maximum

 

approved

 

CAT5

 

cable

 

length

 

is

 

100

 

meters

 

per

 

zone.

 

   

ZONE4R

 

zone

 

select

 

switch

 

at

 

the

 

back

 

of

 

the

 

ZONE4R

 

unit.

 

 

ZONE4R

 

optional

 

accessories:

  

 

RJ45SPLIT:

 

1

 

in/4

 

out

 

straight

 

through

 

RJ45

 

splitter

 

box

 

(dimensions

 

mm

 

:

 

105L

 

x

 

42W

 

x

 

28D).

 

This

 

unit

 

can

 

not

 

be

 

housed

 

in

 

a

 

back

 

box.

 

  

The

 

RJ45

 

input

 

is

 

located

 

at

 

the

 

side

 

of

 

the

 

unit

 

 

BB1

 

:

 

ZONE4R

 

on

wall

 

back

 

box

 

(HxWxD

 

:

 

80

 

x

 

114

 

x

 

48

 

mm)

 

 

 

BBI1

 

:

 

ZONE4R

 

in

wall

 

back

 

box.

 

 

ZONE4R

 

is

 

also

 

compatible

 

with

 

BTicino

 

503E

 

in

wall

 

boxes

 

or

 

503NP

 

on

wall

 

boxes.

  

Содержание ZONE4R

Страница 1: ... the knob to mute the music the mute status is indicated by led 4 2 Display this shows the selected music line source A to D or the music or microphone levels When a value has been edited the display lights up more strongly during a few seconds After a few seconds the display will show the selected music source again Please note that after some time of non operation the intensity of the display wi...

Страница 2: ...s see table below RJ45 connections on rear of ZONE4 main unit to zone remote wall panels Æ Æ Pin number RJ45 T 568A cable colour code T 568B cable colour code Euroblock 4 see picture above Pin 1 GND white green white orange connector 1 Pin 2 12 VDC green orange connector 4 Pin 3 GND white orange white green connector 1 Pin 4 Rx B blue blue connector 2 Pin 5 Tx A white blue white blue connector 3 P...

Страница 3: ...You can connect multiple ZONE4R units to the ZONE4 main unit using a straight through CAT5 cable hub You can assign multiple ZONE4R units to the same zone The maximum number of ZONE4R units connected to a single ZONE4 unit is 8 pieces Maximum approved CAT5 cable length is 100 meters per zone ZONE4R zone select switch at the back of the ZONE4R unit ZONE4R optional accessories RJ45SPLIT 1 in 4 out s...

Страница 4: ...8A or T 568B are possible For details about wiring please refer to the wiring details and colour code T 568B termination is not recognized in the USA but is considered as standard cable termination in many other countries Dimensions Front plate dimensions 114 x 80 mm Mounting hole spacing 83 mm Cutout dimensions without using a backbox 70W x 55H mm mounting depth 40 mm ...

Отзывы: