background image

7

 

!

the “

View

” button, in the dialog box select the 

DRIVERS

 folder, press the “

Continue

” button, when the warning 

Installing a device

” appears, press “

Continue anyway

.”

 

4. The virtual COM port ”

CDC USB to UART

”  is installed; press “

Finish

.” 

5. The system then detects and installs the “

Mass storage device

” -> “

ATMEL MASS STORAGE USB Device

” -> “

Disk 

drive

.”

 

After the installation is completed, the recorded is listed in the system as a virtual COMx port (x-port number: 1, 2, 
...) and two exchangeable disks: internal memory 4 MB with the AR234 label and SD/MMC memory (available after 
the card is put in the “SD/MMC CARD” slot). In the internal memory the configuration text file 

AR234.cfg

 can be 

seen (chapter 9). 
 

NOTE

:  

Do not disconnect the device from the computer before the installation of drives is completed and whenever the 
device is connected again to the USB port when disks are being detected (when the 

[READ/WRITE]

 LCD is on; see 

chapter 5). 
 
 

8. INSTALLATION OF SOFTWARE

 

 
In the "

SOFTWARE

" folder of the CD-ROM that is provided with the device there is a free software installation set 

for the recorder. The set contains the following applications: 

ARSOFT-CFG WZ1

   - display of current measurement data, battery voltage, and date and time;  

- configuration of the real time clock (

RTC

) and other parameters, such as type of 

measurement input, ranges of indications, recording options, alarms, display, access options 
etc. (chapter 9), the software requires communication with the recorder via the USB port - 

on-line configuration

 

ARSOFT-WZ3

  

- presentation, in a graphic form or as text, of results, with the possibility to print; input data 
is uploaded one time from a “csv” text file created in the internal memory in the recorder or 
on an SD/MMC card (chapter 11) 

 

The latest

 versions of the aforementioned programs are also available at the website (www.apar.pl). The detailed 

descriptions of the aforementioned applications can be found in the installation folders. 

 

9. SETTING OF THE CONFIGURATION PARAMETERS

 

All the configuration parameters of the recorder are stored in the non-volatile FLASH internal memory in a text file: 

AR234.cfg

.” 

When the device is switched on for the first time, an error message may be shown in the display due to the lack of 
a sensor or the fact that the sensor that is connected is not one that is factory-programmed. In such an event, the 
proper sensor or analog signal must be connected and the configuration must be programmed. 
There are parameter configuration methods: 

1.

 Use the USB port and the ARSOFT-CFG WZ1 software (

on-line configuration

):  

 

connect the recorder to a computer port and to start the ARSOFT-CFG WZ1 application 

 

after the connection has been established, the current measured values, the battery voltage, and the 
internal time and date of the recorder are displayed in the software’s window;

 the “

STATUS

” LED indicates 

the presence of transmission

 

 

setting and viewing of the device parameters is possible in the parameter configuration window 

 

new parameter values must be approved with the 

Approve changes

 button 

 

the software enables synchronization of the time and the date with the computer 

 

the current configuration can be saved in a file or set using values read from a file 

 

the recorder updates the 

“cfg”

 

configuration file after it is disconnected from the USB port of the computer 

(provided that battery voltage > 3 V)

 

Содержание AR234

Страница 1: ...USER INSTRUCTION DATA RECORDER AR234 Version 1 0 5 2016 07 08 ...

Страница 2: ...NAND THE ELECTRICAL CONNECTIONS 6 7 CONNECTING TOA COMPUTERAND INSTALLATION OF DRIVERS 6 8 INSTALLATION OF SOFTWARE 7 9 SETTING OF THE CONFIGURATION PARAMETERS 7 9 1 TIMEAND DATE 9 9 2 RECORDING OPTIONS 9 9 3 CONFIGURATION OF THE MEASUREMENT INPUT 9 9 4 ACCESSAND IDENTIFICATION OPTIONS 10 9 5 DISPLAY OPTIONS 11 9 6 CONFIGURATION OF THEALARM OUTPUT 11 10 USEAND FUNCTIONS OF THE SD MMC CARD 12 11 VI...

Страница 3: ...ttery LCD display that shows the measured values messages and errors long operation time with a new battery up to 5 years depending on the recording interval the presence of an SD card the operating temperature of the device and the mode of operation of the display possibility to transfer archived and configuration data on an SD card internal real time clock with a battery backup power supply comp...

Страница 4: ...omputer 2 m long a CD with the drivers and the software Windows XP Vista 7 8 10 a user instruction a warranty card 4 TECHNICAL DATA A universal input programmable measurement range Pt100 RTD 3 or 2 wire 200 850 C Ni100 RTD 3 or 2 wire 50 170 C thermocouple J 40 800 C thermocouple K 40 1200 C thermocouple S 40 1600 C thermocouple B 300 1800 C thermocouple R 40 1600 C thermocouple T 25 350 C thermoc...

Страница 5: ...ABS UL94 V0 white Protection rating IP20 no protection against ingress of water and condensation Enclosure dimensions 80 x 80 x 25 mm Operating position any Weight approx 100 g with a battery Electromagnetic compatibility EMC immunity according to the PN EN 61000 6 2 2002 U standard emissivity according to the PN EN 61000 6 3 2002 U standard 1 operation time depends on the measurement period the p...

Страница 6: ...indows XP Vista 7 8 10 system detects the recorder named APAR USB DEVICE and demands installation of drivers In the find new device wizard manually indicate the location of the drivers on a CD ROM the DRIVERS catalog In the Windows XP system the installation procedure is the following 1 Choose the option No not this time and press the Continue button 2 Choose Install from a list or a specific loca...

Страница 7: ...bility to print input data is uploaded one time from a csv text file created in the internal memory in the recorder or on an SD MMC card chapter 11 The latest versions of the aforementioned programs are also available at the website www apar pl The detailed descriptions of the aforementioned applications can be found in the installation folders 9 SETTING OF THE CONFIGURATION PARAMETERS All the con...

Страница 8: ... memory to save archive files to record data CONFIGURATION OF THE MEASUREMENT INPUT chapter 9 3 5 inp type of measurement input 6 rrtd total resistance of leads for 2 wire RTD sensors and 700 Ω 7 cjte temperature of cold thermocouple tips 8 dot position of the point resolution 9 rbot bottom of the indication range start of the scale for 0 mA 4 mA 0 V 0 mV and 0 Ω 10 rtop top of the indication rang...

Страница 9: ...9 59 2008 06 01 00 00 00 2 Stop recording end time 1 date 01 06 2008 31 12 2099 time 00 00 00 23 59 59 2008 06 01 00 00 00 3 MPer 2 data recording interval 10 s 24 hrs increment 10 s 10 s 4 SDest the memory where the archive files csv are to be recorded 3 internal The csv files are created only in the internal memory auto automatic selection auto archive files csv are created only on an SD MMC car...

Страница 10: ... zero offset 50 0 50 0 C or 500 500 units 2 0 0 C 12 calG calibration of the inclination sensitivity gain 85 0 115 0 100 0 Notes 1 in the case of 3 wire sensors there is automatic line resistance compensation and parameter 6 rrtd must be equal to 0 00 Ω 2 applies to analog inputs mA V mV Ω 9 4 ACCESS AND IDENTIFICATION OPTIONS Table 9 4 Configuration parameters concerning the access and identifica...

Страница 11: ...guration parameters Parameter Range of variability of the parameter and description Default settings 17 LCDmod 1 display operation mode economy or continuous econom 18 LCDupd 1 interval of display update in the continuous mode 10 s 24 hrs 10 s increment 2 minutes 19 LCDch value to be displayed measurement and internal temperature measurement and int temp measurement only 9 6 CONFIGURATION OF THEAL...

Страница 12: ...ith off line configuration consequently an appropriate cfg file must be present or absent when parameter 15 Prot off so as to avoid undesirable reconfiguration of the recorder in order to extend the operation of the battery it is recommended to use SD MMC cards of reputable brands e g SanDisk Kingston or GoodRam formatted in the FAT16 file system in the case of cards larger than 2 GB there is a ri...

Страница 13: ...fferent than the one that is set in the configuration chapter 9 3 parameter 5 inp b other elements indicated by the LED s on the side of the housing and on the LCD display LED Description of message READ WRITE writing to reading from the internal memory or the SD MMC card also during recording of a measurement recording is active a short flash every 10 seconds STATUS transmission through the virtu...

Страница 14: ...ass memory is supported internal memory or the SD MMC card and during operation of the ARSOFT CFG WZ1 software keep a copy of the current configuration file AR234 cfg in external memory SD MMC card computer disk etc for the purpose of archiving and future off line configuration If the recorder does not respond the battery can be taken out for a short time and its charging level can be checked if t...

Отзывы: