7.3.3   

Multiviewer Connection Specific Setup 

 

The areas outlined in red in the figure below pertain to configuring all the multiviewers 

which the CP-16 module will control and which buttons will control which multiviewer/s. 

 

 

Figure 7.3b:    Administration Tab, Multiviewer specific settings 

 

Содержание CP-16

Страница 1: ...CP 16 User Manual ...

Страница 2: ...ive Product or c if after a reasonable time is unable to correct the defect or provide a replacement Product in good working order then the purchaser shall be entitled to recover damages subject to the limitation of liability set forth below Limitation of Liability Apantac s liability under this warranty shall not exceed the purchase price paid for the defective product In no event shall Apantac b...

Страница 3: ...Panel 2 5 0 Accessories 3 6 0 Installation 4 7 0Configuration and Programming 5 7 1 Getting Started 5 7 2 Connecting to the CP 16 with a Web Browser 5 7 3 CP 16 Administration Setup 6 7 3 1 CP 16 Module Setup 7 7 3 2 Multiviewer Connection Setup 9 7 4 CP 16 Programming and GPIO Setup 11 7 4 1 Button Programming 12 7 4 2 GPIO Control Setup 13 7 5 CP 16 Advance tab 14 Appendix I AXP Commands 15 Appe...

Страница 4: ... GPI triggers Built in web page setup can be easily accessed by any web browser 3 0 Specifications Description 16 Button Control Panel Software Built in web interface Connectors IP 100 Base Tx Ethernet TCP IP on RJ45 port GPIO 8 lines on 10 wire RJ50 port adapter cable breakout provided RS232 Serial on RJ45 connector adapter cable provided Serial port use not currently available in firmware EMI RF...

Страница 5: ...APANTAC LLC 10200 SW Allen Blvd Beaverton OR 97005 Support Apantac com TEL 1 503 968 3000 2 4 0 Front Rear Panels 4 1 Front Panel Figure 4 1 CP 16 Front Panel 4 2 Rear Panel Figure 4 2 CP 16 Rear Panel ...

Страница 6: ...C 10200 SW Allen Blvd Beaverton OR 97005 Support Apantac com TEL 1 503 968 3000 3 5 0 Accessories Power Adapter 2 x Mounting Plate RJ50 to DB9 Cable for GPI O RJ45 to DB9 Cable for RS 232 Terminal Block for GPI O ...

Страница 7: ...the RJ50 DB9 adapter cable NOTE The RJ50 connector has 10 contacts and a metal shielded end GPI inputs can be provided by either relay contact closures or open collector circuits of external equipment GPI connections must include the ground GND reference The input is activated when it is brought to the ground reference level GPO outputs provide a 5volt output level from the CP 16 when active and g...

Страница 8: ... section will help you get the CP 16 up and running with the built in web page setup as quickly as possible 7 2 Connecting to the CP 16 with a Web Browser The default address for the CP 16 is 192 168 1 151 Open a web browser and type 192 168 1 151 in the URL address line When connected the login page will be displayed The default username is apantac the default password is apantac The username and...

Страница 9: ...005 Support Apantac com TEL 1 503 968 3000 6 7 3 CP 16 Administration Setup After you logon to the CP 16 page you will be able to access 3 tabs Setup Advance and Adminstration Click the Administration tab Figure 7 2 Administration Tab CP 16 settings ...

Страница 10: ...g the setup webpages difficult If your I T department insists on DHCP they should program their DHCP server router to assign a known preselected IP Address to the CP 16 unit To apply these changes click the Apply button at the bottom of this webpage and then click the Reboot button on the Setup tab NOTE If DHCP is Enabled the following four network settings will be ignored Your Network s DHCP serv...

Страница 11: ...nly computers with these IP addresses can login to the CP 16 s webpages IP 1 through IP 4 Enter the IP addresses of the computer s to be permitted to login to access and change the CP 16 s settings Control This will enable or disable the Accessible IP Setting function and settings See the above warning prior to enabling this function ...

Страница 12: ...t Apantac com TEL 1 503 968 3000 9 7 3 2 Multiviewer Connection General Setup The areas outlined in red in the figure below pertain to the CP 16 module connecting to the multiviewer s it will control Figure 7 3 Administration Tab Multiviewer general settings ...

Страница 13: ...ize TCP protocol Transmit Timer Transmission timeout limit Default is 100 Change to 200 or 300 ms if experiencing trouble with the multiviewer not receiving commands and no other reason can be found Server Client Mode CP 16 to Multiviewer communication mode Default is Client and cannot be changed Server Listening Port Not applicable to the CP 16 functionality Default is 2009 ...

Страница 14: ...000 11 7 3 3 Multiviewer Connection Specific Setup The areas outlined in red in the figure below pertain to configuring all the multiviewers which the CP 16 module will control and which buttons will control which multiviewer s Figure 7 3b Administration Tab Multiviewer specific settings ...

Страница 15: ... chosen above Assign to AXP Ctrl Number Enter which buttons will send their commands to this multiviewer Host Number Acceptable numbers are 1 through 16 Separate the button numbers by a period character Setting this parameter to 0 zero will assign no buttons to this host effectively disabling the host Client Destination Host Name IP Enter the IP addresses of the Apantac Tahoma Multiviewer to be as...

Страница 16: ...tiviewer Client Destination Host Number Assign to AXP Ctrl Number Client Destination Host Name IP Client Destination Port 1 Host 1 1 2 3 4 192 168 1 151 101 2 Host 2 5 6 7 8 192 168 1 152 101 3 Host 3 9 10 11 12 192 168 1 153 101 4 Host 4 9 10 11 12 192 168 1 154 101 5 Host 5 9 10 11 12 192 168 1 155 101 Host 6 0 n a n a Host 16 0 n a n a Procedure 1 Select Host 1 in the pulldown click the Apply b...

Страница 17: ... LLC 10200 SW Allen Blvd Beaverton OR 97005 Support Apantac com TEL 1 503 968 3000 14 7 4 CP 16 Programming and GPIO Setup The Setup tab provides for button programming and for GPIO setup Figure 7 4 Setup Tab ...

Страница 18: ...ult is AXP CMD Reserved is for future firmware options and currently performs no function GPIO Button Mode See the next section AXP Ctrl 0 AXP Ctrl 15 Type the desired AXP command here for buttons 1 through 16 Click the Apply button at the bottom of the page then the confirmation popup box to complete the programming change AXP Examples To load a preset configuration file stored within the multivi...

Страница 19: ... be used to trigger any external equipment Apantac Tahoma Multiviewer s also have a GPIO port and the CP 16 GPO can be used to trigger these inputs if desired The multiviewer must be configured to respond to GPIO inputs AXP CMD GPI When this option is selected the GPIO port on the back of the CP 16 is configured for input An internal 5 volt source is provided through a pull up resistor All inactiv...

Страница 20: ...etup and service Firmware Upgrade Settings For use by authorized service personnel only Contact Apantac Technical Support prior to making any changes on this page Auto Warning Report Settings When certain setup actions are performed an alternate webpage is displayed as standard warnings These are enabled by default and there are no reasons to alter these settings ...

Страница 21: ... 1 thru 1 4 1 inputs 2 1 thru 2 4 7 inputs 8 1 thru 8 4 Type SDI AES AA Type of audio format SDI embedded AES or AA discrete input audio Input_ 1 4 SDI type only Video input number within the VPM Group 1 4 SDI only SDI embedded audio group number Channel Pair 1 4 SDI 1 8 AES or AA SDI channel number AES AA channel pair number Examples Command Description Audio 3 SDI 1 2 3 Select SDI input 1 from V...

Страница 22: ...om TEL 1 503 968 3000 19 Load Load a display configuration from a saved preset file Load FILE_NAME Parameters Values Description file_name The preset file name The file name must be bracketed with Examples Command Description Load 1_full pt1 Loads preset name 1_full pt1 ...

Страница 23: ... known as Null Modem adapters or cables RJ45 DB9 Adapter Cable Cross over Serial Cable 2 Power on the CP 16 unit 3 Launch the HyperTerminal program on your PC 4 Configure HyperTermianl to use the serial port with the following setup 5 Key in the factory reset command dft net then click Enter Note insert a space after dft and a space after net 6 Power reset the CP 16 unit 7 You can now connect to t...

Страница 24: ...ssage approximately every 5 seconds Make a TCP connection with host ip 192 168 1 151 at port 101 After typing the dft net command and pressing enter the CP 16 will return the following acknowledgement AXP CMD 12 CFG Default setting Rx dft cfg dt You can now dis connect and close HyperTerminal and reboot the CP 16 unit If HyperTerminal is left connected during the CP 16 reboot it will receive a num...