background image

Intelligent 

Remote 

Control

Cleaning time /Air volume output adjustable

Cleaning time setting

Set a reminder for the cleaning time at will. Blue light flashes indicates cleaning is required. The electrode needle 
cleaning cycle should be set according to the working environment when using the ionizing air blower. Cleaning 
cycle should be shorten appropriately in environment with more moisture and dust.

Air volume output adjustable

Fan speed in five gears. Adjust the air volume according to the installation distance of the static eliminator and the 

status of the target object.

Ion balance adjustable

The ion balance voltage can be adjusted by adjusting the negative high voltage 

amplitude remotely.

Function

Symbol

Operation instructions

Unlock

Unlock before adjusting operating parameters; 30s delay if any key is 

pressed, exit and re-locked if no key is pressed.

Run

 / 

Pause

Device starts running when power is on. Press "STOP" to standby and no 

high voltage output.  Press "RUN" again and the device will start working.

Clean

Press the button to clean the needle once.

Adjust clean time

CT

TH

→ +/-

Press CT

TH

 first, and then press +/- to increase or decrease the 

cleaning cycle. Minimum adjustment unit 1H.

Adjust air volume

CFM → +/-

Press CFM first, then press +/-,air volume from high to low is 1,2,3,4,5.

Adjust ion balance

IB

→ +/- 

    

Press IB

first, then press +/- to adjust the ion balance voltage.

Confirm

CAL → OK

Note: Press CAL first, then press OK to confirm after adjusting the 

output parameter; otherwise, false alarms are likely to occur.

Reset

 

Reset

(150Hz、50%、4H):

Press

 CAL 

first

then

 

press

Press IB

N

 first, then press + when the positive voltage on flat panel charge detector or object surface is high, press IB

N

 first, then press - when 

the negative voltage on flat panel charge detector or object surface is high

 u

ntil the ion balance reaches the ideal status.

CAL →

TIME

TIME

Reduce

 the negative high voltage amplitude

,

  

the negative ion output decreases

Adjust ion balance voltage

Button Function 

instructions

Содержание AP-DJ1811

Страница 1: ...Intelligent control ionizing air blower AP DJ1811 Shanghai Anping Static Technology Co Ltd AP TR AP T New Product Intelligent Control Ionizing Air Blower...

Страница 2: ...ms caused by static electricity Suitable for electronics optoelectronics semiconductor and other industries Prevent adhesion of objects Static removal Prevent blockage of feeder Prevent static electri...

Страница 3: ...networking methods to monitor the working status of ionizing air blower online RS485 communication AP DY6703 AP KT3701 AP DY6704 USB wire link USB wire link IMS monitoring software IMS monitoring soft...

Страница 4: ...rts running when power is on Press STOP to standby and no high voltage output Press RUN again and the device will start working Clean Press the button to clean the needle once Adjust clean time CTTH P...

Страница 5: ...nation ability can be exerted no matter in short or long distance In addition the high voltage amplitude can be adjusted which is convenient for intelligent control Pulse DC VS Traditional AC AC High...

Страница 6: ...instrument Trek charge plate tester Test voltage 1000V 100V attenuation Test environment humidity 50 5 temperature 23 3 Test bearing chart of single port air blower Z mm Trek 150 150mm flat tester 150...

Страница 7: ...les per air outlet with longer life time No 3 Built in cleaning brush Automatic needle brushing function when start up By default the needle is automatically brushed every 4 hours for manual cleaning...

Страница 8: ...higher than ordinary fans CE certification CE certified with electromagnetic protection function and no electromagnetic interference to other equipment It can also effectively avoid external electroma...

Страница 9: ...or cleaning indication 9 Metal shield PE The output wiring diagrams of pins 7 and 8 are as follows 8 VKDSHG EUDFNHW RJ45 power communication interface URXQG 6WXG 3RZHU VZLWFK OHDQing VZLWFK LU YROXPH...

Страница 10: ...ning prompt blue light flashing Communication method RS485 Signal output RS485 115200bps 8 1 n n 20ms Collector open circuit 50V 100mA Working temperature 0 50 Working humidity 70 RH Dimensions 147 70...

Страница 11: ...ce of the charged body 2 Ionizing air blower should be at least 300mm away from the metal conductor and metal grounding body The ionizing air blower must be reliably connected to the ground wire 3 Two...

Страница 12: ...or wrong product power supply line 8 The product is smoky or burnt The high voltage module is damaged or the insulation of the discharge bracket is damaged Return to factory for maintenance 1 Please...

Страница 13: ...hen repairing 2 Do not press or rotate the control buttons on the fan panel too hard otherwise the device will be permanently damaged 3 If the working indicator light on the front panel of the fan is...

Страница 14: ...ing analysis and elimination solution provider Shanghai Anping Static Technology Co Ltd Tel 86 21 64517676 Fax 86 21 64517673 Postcode 200233 Website www ap static com Address 3 F Building 27 No 69 Gu...

Отзывы: