No.

Faults

Reasons

Solutions

1

The indicator on the fan 

panel is off

Poor contact of the power cable

Check whether the power cable is in good condition and  

securely connected

Power supply mismatch

Confirm the power supply specification

INPUT

100—240VAC 

50/60Hz

OUTPUT

24VDC 2000mA

2

The electrostatic removal

 

performance decreased 

obviously.

Discharge needle is polluted and damaged

Clean or replace the discharge needle

The cleaning brush covers the electrode needle

Brush the needle manually with the remote control, or shut down and 

restart to keep the cleaning brush away from the electrode needle

Ionizing air blower is set incorrectly

Confirm the best installation location

3

The electrostatic removal

 

performance decreased

There are conductors or other 

ionizing air blower around 

4

High  voltage  alarm

Panel 

indicator light flashes red

Electromagnetic interference

Turn off the power switch / unplug the power cable, restart 

the ionizing air blower

Abnormal discharge

Confirm whether the electrode needle is close to or touching 

the metal conductor, and remove foreign objects

No power supply for high voltage module

Return to factory for maintenance

High voltage module is damaged

Return to factory for maintenance

5

Fan alarm

Panel indicator red 

light always on

Fan fault

Return to factory for maintenance

The fan power supply

 or 

control 

circuit

 is damaged

Return to factory for maintenance

6

Unable to discharge

Return to factory for maintenance

Main-board chip is damaged

Return to factory for maintenance

Poor grounding / chip damage caused by no grounding Check the grounding of the ionizing air blower and plant equipment, 

and return to the factory for maintenance

7

The display is off or flickering

Abnormal discharge

Return to factory for maintenance

High voltage module is damaged

Return to factory for maintenance

Poor grounding or wrong product power supply line

8

The product is smoky or burnt

The high-voltage module is damaged or the insulation 

of the discharge bracket is damaged

Return to factory for maintenance

1.

Please read the instruction manual carefully before installing and using this equipment.

2.

 The whole set of equipment must be reliably grounded during use, and the connection resistance of the electrical connection to the AC 

equipment ground should be less than 1 ohm.

3.

Do not use this equipment in environment where humidity is > 70%..

4.

It is strictly forbidden to use this equipment in flammable and explosive environments.

5.

Unauthorized disassembly of the product is strictly prohibited, internal maintenance and repair must be performed by professionals.

6. The product is strictly prohibited to touch liquid during use

, otherwise an abnormality may occur and cause electric shock or fire.

7.

Power must be turned off during inspecting or replacing the product, otherwise it may cause electric shock or fire.

8.

The product is specially designed to eliminate static electricity. It is strictly forbidden to use it for other purposes. Any abnormal use may 

cause machine failure, electric shock, fire and other accidents.

9.

 It is strictly forbidden to touch the electrode needles when power is on, otherwise it is easy to cause malfunctions and electric shock 

accidents.

10.

The electrode needle is a sharp metal object,  please use it with care.

11.

 Please check the specifications of the power supply before powering on the product. Any power supply that does not meet the 

specifications will cause damage to the product.

12.

Please check the product power cord/communication cord regularly, and replace it immediately if it is damaged, otherwise it is easy to 

cause problems such as electric leakage, poor communication, and abnormal operation.

Safety warning

Trouble shooting

Remove (moving) conductors or other ionizing air blowers

High voltage module is damaged

Check the grounding of the ionizing air blower and plant equipment, 

and return to the factory for maintenance

Содержание AP-DJ1811

Страница 1: ...Intelligent control ionizing air blower AP DJ1811 Shanghai Anping Static Technology Co Ltd AP TR AP T New Product Intelligent Control Ionizing Air Blower...

Страница 2: ...ms caused by static electricity Suitable for electronics optoelectronics semiconductor and other industries Prevent adhesion of objects Static removal Prevent blockage of feeder Prevent static electri...

Страница 3: ...networking methods to monitor the working status of ionizing air blower online RS485 communication AP DY6703 AP KT3701 AP DY6704 USB wire link USB wire link IMS monitoring software IMS monitoring soft...

Страница 4: ...rts running when power is on Press STOP to standby and no high voltage output Press RUN again and the device will start working Clean Press the button to clean the needle once Adjust clean time CTTH P...

Страница 5: ...nation ability can be exerted no matter in short or long distance In addition the high voltage amplitude can be adjusted which is convenient for intelligent control Pulse DC VS Traditional AC AC High...

Страница 6: ...instrument Trek charge plate tester Test voltage 1000V 100V attenuation Test environment humidity 50 5 temperature 23 3 Test bearing chart of single port air blower Z mm Trek 150 150mm flat tester 150...

Страница 7: ...les per air outlet with longer life time No 3 Built in cleaning brush Automatic needle brushing function when start up By default the needle is automatically brushed every 4 hours for manual cleaning...

Страница 8: ...higher than ordinary fans CE certification CE certified with electromagnetic protection function and no electromagnetic interference to other equipment It can also effectively avoid external electroma...

Страница 9: ...or cleaning indication 9 Metal shield PE The output wiring diagrams of pins 7 and 8 are as follows 8 VKDSHG EUDFNHW RJ45 power communication interface URXQG 6WXG 3RZHU VZLWFK OHDQing VZLWFK LU YROXPH...

Страница 10: ...ning prompt blue light flashing Communication method RS485 Signal output RS485 115200bps 8 1 n n 20ms Collector open circuit 50V 100mA Working temperature 0 50 Working humidity 70 RH Dimensions 147 70...

Страница 11: ...ce of the charged body 2 Ionizing air blower should be at least 300mm away from the metal conductor and metal grounding body The ionizing air blower must be reliably connected to the ground wire 3 Two...

Страница 12: ...or wrong product power supply line 8 The product is smoky or burnt The high voltage module is damaged or the insulation of the discharge bracket is damaged Return to factory for maintenance 1 Please...

Страница 13: ...hen repairing 2 Do not press or rotate the control buttons on the fan panel too hard otherwise the device will be permanently damaged 3 If the working indicator light on the front panel of the fan is...

Страница 14: ...ing analysis and elimination solution provider Shanghai Anping Static Technology Co Ltd Tel 86 21 64517676 Fax 86 21 64517673 Postcode 200233 Website www ap static com Address 3 F Building 27 No 69 Gu...

Отзывы: