4
GAS REQUIREMENTS
The pressure adjuster should comply with the standard EN16129 and current regulations in the country where it
is installed, which may be found at your nearest retailer of gas items.
Refer to the technical date. It is strictly prohibited to use adjustable pressure.
The life expectancy of the regulator is estimated as 10 years. It is recommended that the regulator is changed
within 10 years of the date of manufacture or the national conditions require it.
The type of replaceable hose should meet the standard of EN16436-1.
The length of the hose must be 0.4 meters (minimum) and 1.0 meters (maximum). Worn or damaged hose must
be replaced. Ensure that the hose is not obstructed nor kinked. It is recommended that the hose is changed
within 1 year of the date of manufacture or the national conditions require it.
Never use a gas cylinder with a damaged body, valve, collar, or foot ring. A dented or rusty gas tank may be
hazardous and should be checked out by a gas supplier.
Always perform a leak test on gas connections whenever a cylinder is connected. If bubbles form in the leak test
solution, do not use. Never use a flame to test for leaks.
Never connect this appliance to an unregulated gas source.
Use only regulator and hose approved for LP Gas at the correct pressures and gas type.
Using 30mbar butane regulator for butane of I3B/P(30) or butane of I3+.
Using 30mbar propane regulator for propane or butane/propane mixture of I3B/P(30).
Using 37mbar propane regulator for propane of I3P(37).
Using 50mbar butane regulator for butane of I3B/P (50).
Using 50mbar propane regulator for propane or butane/propane mixture of I3B/P (50)
CONNECTING TO A GAS CYLINDER
Use max.13kg gas cylinder. Please refer to your gas supplier for suitable gas cylinder.
Refer to your gas supplier for instructions on the use of your gas cylinder.
Only change gas cylinders outdoors or in a well ventilated area away from naked flames and any other source of
ignition.
The gas cylinder must always be used in an upright position.
Close the appliance control knob by turning fully clockwise.
Close the gas cylinder tap and then attach the regulator onto the gas cylinder.
Tighten all connections firmly and with a spanner where appropriate.
The cylinder should be located on the cylinder base.
Check for leaks at all joints using soapy water. If a leak is found, tighten the
joint and then re-test.
SECURING A GAS CYLINDER
1. Position a gas cylinder inside the tank housing.
2. Stick cylinder restraint straps together as RIGHT photo illustrated.
The straps must be in a proper tightness for the gas cylinder.
Caution: Please take care that the cylinder restraint straps. DO NOT strain
the regulator assembly.