66
TC5-1N5FAB rev.06
TC5-1N5FAB
POSITION
DISPLAY
MEANING
STAGE 2 / 3
St.2 / Str
Stage 2 differential (start temperature)
St.3 / Oft
Stage 3 offset
St.3 / Str
Stage 3 differential (start temperature)
CURTAINS - DEAD
BAND / TIMER
Deb
Curtain Dead Band
ON
Time on
OFF
Time off
Aut /
Off /
OPE /
CLO
Aut - automatic mode
Off - manual off
OPE - manual open
CLO - manual close
CURTAINS -
MANUAL
Aut /
Off /
OPE /
CLO
Aut - automatic mode
Off - manual off
OPE - manual open
CLO - manual close
MIST
TIMER/
OFFSET/
DIFF.
Oft / StP
Mist offset (stop temperature).
diF / Str
Mist differential (start temperature).
On
Time on for mist cycle.
Off
Time off for mist cycle.
StP rH
Humidity turn off level.
7
TC5-1N5FAB rev.06
TC5-1N5FAB
LED
MEANING
STAGE 1
TURNS ON WHEN STAGE 1 FANS ARE ON.
STAGE 2 / 3
FLASHES WHEN STAGE 2 FANS ARE ON. TURNS ON WHEN STAGE
3 FANS ARE ALSO ON.
CURTAI N S
FLASHES WHEN CURTAINS ARE CLOSING. TURNS ON WHEN
CURTAINS ARE OPENING.
MI S T
TURNS ON WHEN MIST UNITS ARE ON.
HEATER 1
TURNS ON WHEN HEATER 1 IS ON.
HEATER 2
TURNS ON WHEN HEATER 2 IS ON.
DEF. P R OBE/
ALARM
TURNS ON WHEN AN ALARM IS DETECTED. BLINKS WHEN A
DEFECTIVE PROBE IS DETECTED.
COMPENSATION
TURNS ON WHEN THE COMPENSATION ON STAGE 1 MINIMUM
VENTILATION SPEED IS IN EFFECT OR WHEN THE COMPENSATION
ON THE MIST STAGE IS IN EFFECT.
CONTROLLER STATUS LEDS
#
O F F
O N
1
U N L O C K E D P A R A M E T E R S
L O C K E D P A R A M E T E R S
2
F A H R E N H E IT D E G R E E S
C E L S IU S D E G R E E S
3
P R O B E 2 D IS A B L E D
P R O B E 2 E N A B L E D
4
P R O B E 3 D IS A B L E D
P R O B E 3 E N A B L E D
5
P R O B E 4 D IS A B L E D
P R O B E 4 E N A B L E D
6
O U T S ID E P R O B E D IS A B L E D
O U T S ID E P R O B E E N A B L E D
7
S TA G E 3 C O O L IN G
S TA G E 3 H E A T IN G
8
C A S C A D IN G H E A T E R S
Z O N E D H E A T E R S
9
N O A C T IO N
C L O S E P F -5 B A IR IN L E T O N
C U R TA IN O P E N IN G
1 0
F L O A T IN G S TA G E 3
D IS A B L E D
F L O A T IN G S TA G E 3
E N A B L E D
1 1
R E S E R V E D
1 2
R E S E R V E D
INTERNAL SWITCHES
The internal switches are located on the inside of the front cover. When the
controller is shipped from the factory, all the switches are set to OFF.
ON
2
1
3
4
6
7
5
8
9
11
10
12