14
OPERATING PROCEDURES
7.
To see the running time, or current segment the system is processing or the
temperature of the external temperature probes. repeatedly press the
selection button to switch between different views. Follow the suffix guide to
determine displayed temperature.
8.
After the process is finish the display will show
“End”,
the middle and bottom
display would show the temperature of the probes. Press the increase button
to save the profile and exit to profile adjustment mode.
9.
To exit before the process is finished press the increase button while the
profile is running. The system would exit and return to profile adjustment
mode.
***An alternative way to save the edited profile is to repeatedly press the selection
button until the display shows “Save Prof 0” (the bottom display number should
correspond to the selected profile). Press the up button to save the settings and
jump to profile selection screen. This option is available only for newer software
versions.
Note: There is a built in protection feature to automatically limit the
temperature rising slope to no more than 3 degrees per second. Therefore
the maximum set temperature will be based on your set time.
Preloaded Profile 0:
SEG1 SEG2 SEG3 SEG4 SEG5 SEG6
090t 110t 150t 050t 060t 60t
150C 180C 210C 190C 210C 230C
Segment one is set to 50 seconds to reach 150C. Which means after 50seconds at
the end of segment one the temperature should reach 100C. Then Segment two is
set to 110 seconds to reach 150C, which means by the end of 60 seconds (total
running time after segment two is already 50+110=160 seconds) the set
temperature should reach 150C, so on and so forth.
3
CARE and SAFETY PRECAUTIONS
CAUTION:
Improper usage can cause injury and physical damage.
For your own safety, please observe the following precautions.
●
Temperature may reach as high as 500°C when turned ON.
Do not touch the heating element inside the preheater.
Do not expose skin to infrared light for long periods.
Prolonged exposure may damage the skin tissue.
●
Handle with care
Never drop or sharply jolt the unit.
Contains delicate parts such as IR tubes that may break if the unit
is dropped
Do not spill any liquid to the system.
●
Do not tamper the electrical control unit or any wiring inside the
device.
●
Disconnect plug from main power source if the device will not be used
for a long period.
Turn off power during breaks, if possible.
●
Allow ample time for the equipment to cool down before commencing
maintenance.
●
Use only genuine replacement parts. Turnoff power and let the unit
cool down before replacing any component.