7. 

To see the running time, or current segment the system is processing or the 

temperature  of  the  external  temperature  probes.  repeatedly  press  the 

selection button to switch between different views. Follow the suffix guide to 

determine  displayed temperature. 

8. 

After the process is finish the display will show

 “End”, 

the middle and bottom 

display would show the temperature of the probes. Press the increase button 

to save the profile and exit to profile adjustment mode. 

9. 

To  exit  before  the  process  is  finished  press  the  increase  button  while  the 

profile  is  running.  The  system  would  exit  and  return  to  profile  adjustment 

mode. 

***An alternative way to save the edited profile is to repeatedly press the selection 

button  until  the  display  shows  “Save  Prof  0”  (the  bottom  display  number  should 

correspond  to  the  selected  profile).  Press  the  up  button  to  save  the  settings  and 

jump  to  profile  selection  screen.  This  option  is  available  only  for  newer  software 

versions.

 

Note:  There  is  a  built  in  protection  feature  to  automatically  limit  the 
temperature rising slope to no more than 3 degrees per second. Therefore 
the maximum set temperature  will be based on your set time.

 

Preloaded Profile 0: 

SEG1          SEG2         SEG3         SEG4         SEG5          SEG6 

090t           110t           150t          050t          060t             60t 

150C          180C          210C         190C         210C           230C 

Segment one is set to 50 seconds to reach 150C. Which means after 50seconds at 

the end of segment one the temperature should reach 100C. Then Segment two is 

set  to  110  seconds  to  reach  150C,  which  means  by  the  end  of  60  seconds  (total 

running  time  after  segment  two  is  already  50+110=160  seconds)  the  set 

temperature should reach 150C, so on and so forth.

 

CARE and SAFETY PRECAUTIONS 

CAUTION: 

Improper usage can cause injury and physical damage. 

For your own safety, please observe the following precautions. 

 

Temperature may reach as high as 500°C when turned ON. 

­ Do not touch the heating element inside the pre­heater. 

­ Do not expose skin to infra­red light for long periods. 

­ Prolonged exposure may damage the skin tissue. 

 

Handle with care 

­ Never drop or sharply jolt the unit. 

­ Contains delicate parts such as IR tubes that may break if the unit 

is dropped 

­ Do not spill any liquid to the system. 

 

Do  not  tamper  the  electrical  control  unit  or  any  wiring  inside  the 

device. 

 

Disconnect plug from main power source if the device will not be used 

for a long period.

 

­ 

Turn off power during breaks, if possible. 

 

Allow ample time for the equipment to cool down before commencing 

maintenance. 

 

Use  only  genuine  replacement  parts.  Turn­off  power  and  let  the  unit 

cool down before replacing any component.

Содержание Int732

Страница 1: ...LAY AND OTHER DEVICE OPERATION ISSUES SOLUTION Turn off power and back on OTHER PROBLEMS NOT MENTIONED Contact the vendor AOYUE TONGYI ELECTRONIC EQUIPMENT FACTORY Jishui Industrial Zone Nantou Zhongs...

Страница 2: ...6 SPECIFICATIONS 6 OPERATING PROCEDURES 7 15 BASIC TROUBLESHOOTING GUIDE 16 15 OPERATING PROCEDURES To check the slope from segment Two 150C 180C 30C Time to reach 150C is set to 110seconds Therefore...

Страница 3: ...reloaded Profile 0 SEG1 SEG2 SEG3 SEG4 SEG5 SEG6 090t 110t 150t 050t 060t 60t 150C 180C 210C 190C 210C 230C Segment one is set to 50 seconds to reach 150C Which means after 50seconds at the end of seg...

Страница 4: ...te During segments 1 3 the top heater heats up to 75 of the set temperature at these segments This is to allow a faster ramp up in preparation for reflow for segments 4 6 1 To enter type 2 operation S...

Страница 5: ...at the temperature set at segment 3 Then the last three segments utilizes the top heater to provide the final 25 of the heat to reach reflow 5 FUNCTIONS and FEATURES Multi Point Board Holder Innovativ...

Страница 6: ...button repeatedly until the top display shows TOP and the middle display shows SEt The bottom display would show the current set temperature of the top heater followed by a suffix A 2 Press the incre...

Страница 7: ...y a suffix C Note External temperature probes are labeled Top heater external probe is labeled A while the other two is labeled b and C The displayed actual temperature reading s suffix corresponds to...

Страница 8: ...rature is adjustable from 200 to 480C 3 For the solder iron actual temperature display Follow TYPE 0 OPERATION number 5 see page 10 4 To temporarily turn off the solder iron Simultaneously press both...

Отзывы: