background image

TABLE OF CONTENTS 

CARE & SAFETY PRECAUTIONS ………………..………….. 3 

PRODUCT DESCRIPTION …………………………………… 4 

FUNCTIONS & FEATURES …………………………………… 4 

PACKAGE INCLUSION ……………………………………..  6 

SPECIFICATIONS ……………………………….……………. 6 

OPERATING PROCEDURES ……………………………...  7­15 

BASIC TROUBLESHOOTING GUIDE …………………….... 16

 

15 

OPERATING PROCEDURES 

To check the slope from segment Two : 

 

150C ­ 180C =30C 

 

Time to reach 150C is set to 110seconds. 

 

Therefore the slope is 60/110= 0.54 degrees per second increase.

 

Note: a negative number would denote a declining slope.

Содержание Int732

Страница 1: ...LAY AND OTHER DEVICE OPERATION ISSUES SOLUTION Turn off power and back on OTHER PROBLEMS NOT MENTIONED Contact the vendor AOYUE TONGYI ELECTRONIC EQUIPMENT FACTORY Jishui Industrial Zone Nantou Zhongs...

Страница 2: ...6 SPECIFICATIONS 6 OPERATING PROCEDURES 7 15 BASIC TROUBLESHOOTING GUIDE 16 15 OPERATING PROCEDURES To check the slope from segment Two 150C 180C 30C Time to reach 150C is set to 110seconds Therefore...

Страница 3: ...reloaded Profile 0 SEG1 SEG2 SEG3 SEG4 SEG5 SEG6 090t 110t 150t 050t 060t 60t 150C 180C 210C 190C 210C 230C Segment one is set to 50 seconds to reach 150C Which means after 50seconds at the end of seg...

Страница 4: ...te During segments 1 3 the top heater heats up to 75 of the set temperature at these segments This is to allow a faster ramp up in preparation for reflow for segments 4 6 1 To enter type 2 operation S...

Страница 5: ...at the temperature set at segment 3 Then the last three segments utilizes the top heater to provide the final 25 of the heat to reach reflow 5 FUNCTIONS and FEATURES Multi Point Board Holder Innovativ...

Страница 6: ...button repeatedly until the top display shows TOP and the middle display shows SEt The bottom display would show the current set temperature of the top heater followed by a suffix A 2 Press the incre...

Страница 7: ...y a suffix C Note External temperature probes are labeled Top heater external probe is labeled A while the other two is labeled b and C The displayed actual temperature reading s suffix corresponds to...

Страница 8: ...rature is adjustable from 200 to 480C 3 For the solder iron actual temperature display Follow TYPE 0 OPERATION number 5 see page 10 4 To temporarily turn off the solder iron Simultaneously press both...

Отзывы: