background image

ASLINKTERMINAL 

[ASLINK Small Integrated 16-Point Terminal]

AnyWireASLINK System Products Guide

BL296

B-16F

-4A-20

The 

Products Guide

 describes individual products. Refer to the Guide as necessary.

Function List

  

-BL296*B16F*4A20 1/11-

Connection targets

I/O

short

circuit

Specifications

Model

I/O

disconnection

ASLINKTERMINAL 
four-wire 
(isolated) cable 
type

NPN 16-point input/16-point output
PNP 16-point input/16-point output
NPN 8-point input/8-point output (hybrid)
PNP 8-point input/8-point output (hybrid)

Universal sensors 
and switches, 
universal output 
devices

Small-

sized

Sensing

level

reduction

I/O

 power supply

reduction

Slave unit 

voltage

reduction

[Warranty]

[Notes on Safety]

Precautions that must be observed in order to use this system safely are indicated as shown below. 

You must observe these precautions.

WARNING

CAUTION

A WARNING indicates a potentially hazardous 
situation which, if not handled correctly, could 
result in death or serious injury.

A CAUTION indicates a potentially hazardous situation 
which, if not handled correctly, may result in personal 
injury or property damage.

WARNING

 System Safety

 Always turn off the power before attempting to mount or replace.

This system is intended for general industrial applications. It does not have functions for supporting applications requiring higher 
levels of safety such as safety-related devices or accident prevention systems. The product must not be used for these purposes.

Prolonged continuous flow of a rated load current or higher or a transit current due to load short-circuit, etc., in the hybrid unit including 
the output unit and the output circuit may result in smoking or firing.  An external safety device such as a fuse must be installed.

 Use the 

AnyWireASLINK

 within the range of the specifications and conditions shown below.

 System power supply

 Separately route high-voltage and power cables

 Connectors and terminals

 Do not impose any external loads on the units.  Doing so may cause a failure.

 Do not disconnect or reconnect between the transmission line and slave units. A malfunction may occur.

Use a stable, 24V DC power supply. Use of an unstable power supply may cause problems with the system.

 

Although the 

AnyWireASLINK 

has a high noise margin, keep the transmission line and I/O cables away from high-voltage and 

power cables.

* Pay careful attention to the length and installation of cable wiring to ensure that connectors and cables are neither overloaded nor disconnected.
* Make sure to prevent any metal objects from getting inside the connectors or the terminal blocks.
* Short-circuits caused by metal objects or mis-wiring are likely to damage the device.

CAUTION

 Warranty period

The warranty on the delivered Product shall continue to be effective for one (1) year after the delivery thereof to a location as 

designated by the original owner.

 Scope of warranty

Should a defect occur in any part of the Product during the foregoing warranty period when it is used normally in acordance with 

the specifications described in this User's Manual, the Company shall replace or repair the defect free of charge, except when it 

arises as a result of:

[1] Misuse or abuse of the Product by the owner;

[2] Fault caused by other than the delivered Product;

[3] The unauthorized modification or repair of the Product by any person other than the Company's personnel;

[4] Any unusual force of nature, disaster or other cause beyond the Company's control.

The term "warranty," as used herein, refers to the warranty applicable to the delivered product alone. The Company shall not be 

liable for consequential or incidental damages resulting from any malfunction. 

 Repair at cost

After the expiration of the warranty period, the owner shall be responsible for all costs and expenses incurred for the trouble-

shooting and repair of the Product. Even during the warranty term, the Company shall repair any defects arising from causes 

other than within the scope of the warranty as specified above, at the owner's cost.

Notes on use

 

 

To set any address, an “Address writer ARW-04 (Ver. 04-1.01 or higher),  ARW-03 (Ver. 2.10 or higher)”

                                is required. Please prepare it separately.

[Type]

BL296SB-16F-4A-20
BL296PB-16F-4A-20
BL296XB-16F-4A-20

NPN input
NPN output
NPN input/NPN output

BL296SB-16FS-4A-20
BL296PB-16FS-4A-20
BL296XB-16FS-4A-20

PNP input
PNP output
PNP input/PNP output

×

×

×

Functions

Содержание BL296 B-16F Series

Страница 1: ...ay occur Use a stable 24V DC power supply Use of an unstable power supply may cause problems with the system Although the AnyWireASLINK has a high noise margin keep the transmission line and I O cable...

Страница 2: ...ocation where the atmosphere is free of corrosive gas flammable gas and sulfur Location where the unit is removed from high voltage or high current cables Location where the unit is removed from cable...

Страница 3: ...VE POWER IN SLAVE General purpose power supply filter Use it if necessary General purpose power supply filter Use it if necessary Insert the ASLINK filter Type ANF 01 regardless of installation method...

Страница 4: ...0V PE 24V 0V 24V 0V PE DP DN 24V 0V DP DN 24V 0V 4 wire terminal 4 wire terminal A B Power supply to the entire system Local power supply branching LINE LOAD LINE LOAD AnyWireASLINK master AnyWireASLI...

Страница 5: ...ddress writer The port cannot be seen from the surface The state in which the installation dedicated DIN rail adapter is mounted and fixed in the same direction as the DIN rail The state in which the...

Страница 6: ...10P 4 3 2 1 A B C Cover Pressure weld using a dedicated tool so that the fittings of the body are in the holes of the cover After pressure welding make sure to check that hooks to are securely engaged...

Страница 7: ...damaged Check if the master unit is powered and if necessary please contact our helpdesk 3 If the LINK of the master unit does not flash check if the master unit is powered Other system errors may als...

Страница 8: ...to use a 4 wire insulated terminal Otherwise a malfunction may occur In the case of an inductive load mount a surge killer If the power is turned on with the circuit between OUT and 24V shorted passiv...

Страница 9: ...rminal Otherwise a malfunction may occur In the case of an inductive load mount a surge killer If the power is turned on with the circuit between OUT and 24V shorted passive elements will be damaged C...

Страница 10: ...00Vp p pulse width 1 s Do not preserve or use under an environment pressurized equal to or higher than the atmospheric pressure at the altitude of 0m Power supply voltage use Transmission method Synch...

Страница 11: ...11 11 Printed in Japan 2016 2017 UMA 13221C EN Anywire Corporation Headquarters 1 Babazusho Nagaokakyo shi Kyoto 617 8550 JAPAN Contact by mail Contact info_e anywire jp Contact by website http www an...

Отзывы: