![Anywave ATSC 1KW Скачать руководство пользователя страница 20](http://html1.mh-extra.com/html/anywave/atsc-1kw/atsc-1kw_quick-start-manual_2949028020.webp)
ATSC 1KW TX Quick Start Guide
ACT-1000-QSG-DOC-V1.6, 9/12/2014
Page 20 of 23
8.
Navigate to the AGC screen on the Controller (by pressing the CONFIG
button and then the AGC button). Be sure the AGC Target FWD power is
set to 1000W, or whatever TPO level is desired for operation, and then
press the unlit AGC button to engage the TX AGC and turn this button
Green.
9.
Press the HOME button to return to the HOME screen to monitor FWD
power as it slowly reduces from 1.1 x TPO to the AGC target power
(desired TPO) level over the next minute or so. With the AGC engaged,
the FWD power metering may vary up to +/- 5%, so for a 1000W TX,
meter variations from 950W to 1050W may be experienced.
Set Target AGC Power
to full 1000W or
desired TPO
Press AGC button to
turn AGC ON (will
illuminate Green)