Page 8 of 11 Anyload-manual-indicator-DD-KC1-en-101
windows. Select the connected portal number “COM” and set the baud rate as
9600bps, the parity bit as “NONE”, the data bit as “8Bit”, and the stop bit as
“1Bit”.
c. You can select the serial output modes according to your own needs. The
output modes include 3 types: output by pressing
button, automatic
output after the weight keeps stable, and continuous output. You can set
t
hough the “out” in “Parameter setting”.
d. Output Data Form: 8 bytes data bit + 3 bytes unit code + 2 bytes ending code.
The above-mentioned characters are all ASCII codes, and the unit can be kg, lb
or pcs.
e. The serial ports order can be f0und in
Chapter 2 “button function”.
Example of Output Data
:
Display
Data Bit
Unit Code
Ending Code
1
2
3
4
5
6
7
8
9
1
0
11
12
13
123.45kg
Blank
Blank
1
2
3
.
4
5
k
g
Blank
CR
LF
-123.45lb
Blank
-
1
2
3
.
4
5
l
b
Blank
CR
LF
123.0pcs
Blank
Blank
Blank
1
2
3
.
0
p
c
s
CR
LF
4.10
When the scale is on, press and hold
key until the display "0FF" or "ON",
then release. That means open or close the function of animal weighing. When the
action symbol which is above the units symbol flashes, that means the current mode is
animal mode. in this state, once the weighing is locked, it will automatically remain
locked weighs for about 10 seconds.
5
.
Set User Parameter
a)
Wheb the scale is off, please press
button together with the
button
to turn on the scale. Do not release the
button until the screen displays
“------”
;
b)
Press the
or
button to switch the menu
;
c)
Press the
button to enter the display menu
;
d)
After entering the display menu, press the
or
button to select the