Page 4 of 11 Anyload-manual-indicator-DD-KC1-en-101
4. After entering the display menu, Press
or
key to select
parameters
;
Press
button to verify the parameters and return to the
menu;
5. After all the parameters are set, go to
“-End-”
in the menu, short press
button to save and exit to weighing or counting mode
4.3 Weighing
When power-on, with nothing on the platform, press
button once, the
instrument will then display
“
0
”. Place an object on the platform. After the “
kg
”, “
lb
”
or “
pcs
” character stops flashing, which means that the data is stable, you can
begin to read it.
4.4 Calibration Methods
4.4.1 Random Single-point
Calibration
a) At
weighing mode, press and hold
button until the window
displays“------”;
b) Press
or
button to enter calibration mode;
c) Press
button to make sure enter the calibration mode;
d) After entering the calibration
mode, the window will display“Load”and“0.0kg”
alternately
,
which means that the weight“0.0kg”should be loaded on the
platform
;
e) After making sure that there is nothing on the platform, press
button to
confirm so that the scale begins“0.0kg”calibration. In the process of
“0.0kg”calibration, “0.0kg” will flicker rapidly on the display window
;
keep the
platform calm, stable, and without other interference factors which will influence
Menu
Meaning of Menu
Selective Parameter
1
.
dP
Decimal Point Setting
0/0.0/
0.00
/0.000/0.0000
2
.
CAP
Capacity setting
3000,
6000
,7500,8000,10000,12000,
15000,20000,30000,50000,60000
75000,80000,100000,120000,150000
,200000,300000
3
.
InC
Division setting
d=1/
2
/5
-End-
Save and Exit