Max. Capacity Temp. Drift

Max. Display Resolution

Min. Input Sensitivity

Input signal range

Load cell Excitation 
Voltage

Power Supply

Display:

Display

Sampling Frequency

Display content

Units of Measurement

Enclosure material
IP Rating

Ports

Functions:

Overload protection

User-selectable overload warning value and
alarm value.
Overload warning and alarm can be enabled or
disabled.
Overload alarm peak records can be reviewed.

±

3ppm / 

 Max

1 / 10,000

0.3 

μ

V / e

0mV ~ 

±

25mV

1.22Vdc

3 x AA 1.5V alkaline batteries

6-digit panoramic FSTN LCD with LED back light

4.17 / 6.25 / 8.33 / 10 / 12.5 / 16.7 / 33.2 / 50 / 62 /
123Hz are user-selectable.

Display can show a positive or negative number,
and decimal point can be selected to any position.

kg / lb / t / g / oz / klb / N / kN / are user-selectable
units. Measurements units can be enabled 
independently and switched. The default unit can
be selected.

ABS

IP65

RS-232C (optional)

RS-232C (optional)

Functions

21 set-points calibration, Zero scale, Tare, Low 
battery warning, Peak-hold.

Power-down storage

Power-saving

Date can be saved after power-off.
Date can also be saved after removing batteries.

If inactive for a period of time set by user, the auto
power-saving mode will activate.
If inactive for a period of time set by user, the auto
power-off mode will activate.

Functions:

Zero

Tare In / Tare Out

Hold

Low Voltage Alarm

Battery Supervision

Overload Alarm / Record

Calibration

Digital Calibration

Unit Switch

Gravity Acceleration
Switch

Tare set

Total / Delete / Clear Total

View Total

Resolution Switch

Auto- Off Set

Idle Set

Tare Range

Zero Range

Yes

Yes

Yes (with Peak Hold)

Yes

Yes

2 Alarm Set Point (Lower and Higher)-records
overload

2-set-points calibration is required for linearity
correction

Yes

kg, g, t, lb, Klb, N, kN, oz, User’s defined unit

Yes

Yes

Yes

Yes

Yes

Yes

Yes

100% F.S.

4% F.S.

®

®

Содержание 805HP

Страница 1: ...ww anyload com Email info anyload com Fax 1 866 612 9088 North America Toll Free 1 855 ANYLOAD 269 5623 805HP Handheld Digital Weight Indicator User s Manual V1710 Anyload Transducer Co Ltd Website www anyload com Email info anyload com ...

Страница 2: ...nd panoramic FSTN LCD view angle Material ABS IP Rating Ip65 LCD 6 digit display with LED backlight Non volatile memory for reliable data saving Units of Measurement kg g t lb Klb N kN oz user defined unit Configurable 21 set points for precaution and warning User selectable display interval Overloading recording 10 user selectable analog to digital converting frequency Weight calibration and digi...

Страница 3: ...nd panoramic FSTN LCD view angle Material ABS IP Rating Ip65 LCD 6 digit display with LED backlight Non volatile memory for reliable data saving Units of Measurement kg g t lb Klb N kN oz user defined unit Configurable 21 set points for precaution and warning User selectable display interval Overloading recording 10 user selectable analog to digital converting frequency Weight calibration and digi...

Страница 4: ...owing page 805HP Battery Power indicator Peak hold mode Weights saved to memory Tare value acquired Gross weight mode Cumulate Mode Scale is zeroed Wireless signal strength Load cell battery power indicator dotted line Weight exceeded the maximum capacity overload warning value signal Signal stability Key Functions Power Button Tare Down key Unit Left key Zero Up key Return key Peak Right key Cumu...

Страница 5: ...owing page 805HP Battery Power indicator Peak hold mode Weights saved to memory Tare value acquired Gross weight mode Cumulate Mode Scale is zeroed Wireless signal strength Load cell battery power indicator dotted line Weight exceeded the maximum capacity overload warning value signal Signal stability Key Functions Power Button Tare Down key Unit Left key Zero Up key Return key Peak Right key Cumu...

Страница 6: ...o Normal Weighing Mode Go to Peak mode Holding Cancel Clear peak value Long Press 2 sec Short Press 0 5 sec Switch units Switch units Long Press 2 sec Short Press 0 5 sec Gross Net Weight Tare Untare Gross Net Weight TARE CUMULATE ZERO HOLD UNITS Operation mode Power off Operation mode Power saving Function When the indicator is turned off date will be saved in non volatile memory When the indicat...

Страница 7: ...o Normal Weighing Mode Go to Peak mode Holding Cancel Clear peak value Long Press 2 sec Short Press 0 5 sec Switch units Switch units Long Press 2 sec Short Press 0 5 sec Gross Net Weight Tare Untare Gross Net Weight TARE CUMULATE ZERO HOLD UNITS Operation mode Power off Operation mode Power saving Function When the indicator is turned off date will be saved in non volatile memory When the indicat...

Страница 8: ...er installing the battery long press the on off button for 2 3 seconds then release it The indicator will beep and the screen shows Power off Long press on off button for 2 3 seconds then release it The Ø Ø 6 Start Up and Adjust 6 1 Battery Installation below initialization until reached to indicator weighing system screen shows OFF the indicator is turning off 6 2 Indicator Dimensions 1 1 L H W H...

Страница 9: ...er installing the battery long press the on off button for 2 3 seconds then release it The indicator will beep and the screen shows Power off Long press on off button for 2 3 seconds then release it The Ø Ø 6 Start Up and Adjust 6 1 Battery Installation below initialization until reached to indicator weighing system screen shows OFF the indicator is turning off 6 2 Indicator Dimensions 1 1 L H W H...

Страница 10: ...orresponding wireless transceiver of a wireless scale Usually 805HP WL wireless model is paired with Anyload 110RH WL TENSLINK scale or 110ES WL Salt Waterproof scale If you need to change the indicator s wireless configurations due to radio frequency interference you can configure the communication parameters with the following steps in Section 9 2 The indicator has three 3 weighing modes namely ...

Страница 11: ...orresponding wireless transceiver of a wireless scale Usually 805HP WL wireless model is paired with Anyload 110RH WL TENSLINK scale or 110ES WL Salt Waterproof scale If you need to change the indicator s wireless configurations due to radio frequency interference you can configure the communication parameters with the following steps in Section 9 2 The indicator has three 3 weighing modes namely ...

Страница 12: ...k and the accurate When indicator is set to the Normal Weighing mode Peak mark will not Remove the loads from the scale and wait until Stable mark appears The scale should not in Tare mode and Gross weight mark is on Press ZREO and Zero mark appears Zero the scale setting is completed When no Tare is stored Tare mark does not appear Place the load on the scale and wait until Stable mark appears Pr...

Страница 13: ...k and the accurate When indicator is set to the Normal Weighing mode Peak mark will not Remove the loads from the scale and wait until Stable mark appears The scale should not in Tare mode and Gross weight mark is on Press ZREO and Zero mark appears Zero the scale setting is completed When no Tare is stored Tare mark does not appear Place the load on the scale and wait until Stable mark appears Pr...

Страница 14: ...r when the weight has been tared short press to record the The recently saved weight readings will be displayed in the screen after one second The sign appears in the lower left corner of the screen This means 1 II How to view the cumulative value the middle of the screen Indicator shows as follows peak mode or vice versa III Gross Net Mode vice versa Display shows total gross weight value Gross W...

Страница 15: ...r when the weight has been tared short press to record the The recently saved weight readings will be displayed in the screen after one second The sign appears in the lower left corner of the screen This means 1 II How to view the cumulative value the middle of the screen Indicator shows as follows peak mode or vice versa III Gross Net Mode vice versa Display shows total gross weight value Gross W...

Страница 16: ...D UNITS Add delete decimal point Level 1 Menu 1 Same as above Level 1 Menu 2 Level 1 Menu N Level 2 Menu 1 Level 2 Menu 2 Level 2 Menu N Parameter 1 Parameter 2 Parameter N Same as above Value 1 Value 2 Value N There are 4 directional keys to be used for the operation are used for horizontal movement in the same level menu and parameters are used for moving up and down through Use to choose a para...

Страница 17: ...D UNITS Add delete decimal point Level 1 Menu 1 Same as above Level 1 Menu 2 Level 1 Menu N Level 2 Menu 1 Level 2 Menu 2 Level 2 Menu N Parameter 1 Parameter 2 Parameter N Same as above Value 1 Value 2 Value N There are 4 directional keys to be used for the operation are used for horizontal movement in the same level menu and parameters are used for moving up and down through Use to choose a para...

Страница 18: ...ware mode on off related to the software mode on off related to the software mode on off related to the software mode on off related to the software mode on off related to the software mode dis means that the backlight is always on Basic parameter Settings User s unit coefficient Default unit Any Number related to the software mode kg t g lb oz klb N kN UN Overload Warning on off Overload Warning ...

Страница 19: ...ware mode on off related to the software mode on off related to the software mode on off related to the software mode on off related to the software mode on off related to the software mode dis means that the backlight is always on Basic parameter Settings User s unit coefficient Default unit Any Number related to the software mode kg t g lb oz klb N kN UN Overload Warning on off Overload Warning ...

Страница 20: ...erial com munication on off Baud rate bps 1200 2400 4800 9600 Output DB 8n1 8o1 8e1 Com munication mode Contin reque See note2 See note3 Digit input calibration Standard value Calibration RS232 setting Wireless transmission frequency 2Hz 3Hz 4Hz 5Hz Wireless address 0 255 Any Number Wireless output on off Automatic channel search Manual switching channel 1 16 Wireless gain 1 8 See noet4 Software v...

Страница 21: ...erial com munication on off Baud rate bps 1200 2400 4800 9600 Output DB 8n1 8o1 8e1 Com munication mode Contin reque See note2 See note3 Digit input calibration Standard value Calibration RS232 setting Wireless transmission frequency 2Hz 3Hz 4Hz 5Hz Wireless address 0 255 Any Number Wireless output on off Automatic channel search Manual switching channel 1 16 Wireless gain 1 8 See noet4 Software v...

Страница 22: ...urn to intermittently overload in the menu 8 3 Modify Password password interface the previous menu Details are as follows 9 Communication The 805HP indicator has two ways in communicating to the scale 9 1 RS232 Communication length is 15 meters and beyond this length may lead to a high error rate I Serial communication baud rate to confirm selection II Data frame format 1 1 1 1 The indicator has ...

Страница 23: ...urn to intermittently overload in the menu 8 3 Modify Password password interface the previous menu Details are as follows 9 Communication The 805HP indicator has two ways in communicating to the scale 9 1 RS232 Communication length is 15 meters and beyond this length may lead to a high error rate I Serial communication baud rate to confirm selection II Data frame format 1 1 1 1 The indicator has ...

Страница 24: ...is repeatable until Set communication power To set communication power execute command of the menu Press key to select the power level 1 8 press key to perform the set command When the power settings are successful the indicator displays PASS When the power setting fails the indicator displays FAIL Switching command can be executed repeatedly until transceiver too far and if radio frequency interf...

Страница 25: ...is repeatable until Set communication power To set communication power execute command of the menu Press key to select the power level 1 8 press key to perform the set command When the power settings are successful the indicator displays PASS When the power setting fails the indicator displays FAIL Switching command can be executed repeatedly until transceiver too far and if radio frequency interf...

Страница 26: ...guration menu the indicator shows Remove all loads If hooks or chains are used to hang the test weights load the hooks or chains 2 Press until the indicator shows Press to move into zero A D 3 The indicator shows press to zero calibration The indicator shows the A D count for the zero calibration e g Press again 4 The indicator shows load test weights press The indicator shows the test weight valu...

Страница 27: ...guration menu the indicator shows Remove all loads If hooks or chains are used to hang the test weights load the hooks or chains 2 Press until the indicator shows Press to move into zero A D 3 The indicator shows press to zero calibration The indicator shows the A D count for the zero calibration e g Press again 4 The indicator shows load test weights press The indicator shows the test weight valu...

Страница 28: ...m without using the actual test weights The method requires the A D count Zero offset value Zero offset can be re corrected when using hooks or chains The following describes calibration procedure for digit calibration methods 2 Press until the indicator shows Press to move into zero A D 3 The indicator shows Press and the indicator will show Press to input the new zero A D count Press again 4 The...

Страница 29: ...m without using the actual test weights The method requires the A D count Zero offset value Zero offset can be re corrected when using hooks or chains The following describes calibration procedure for digit calibration methods 2 Press until the indicator shows Press to move into zero A D 3 The indicator shows Press and the indicator will show Press to input the new zero A D count Press again 4 The...

Страница 30: ...press input the cor respon ding A D count 11 Troubleshooting Guides 12 Technical Specifications 1 PROBLEM Defective battery Defective button s Power button not properly pressed Digits flash indicator Display does not respond to load changes Low battery Faulty load cell Display weight shows large error Scale is not Zeroed before applying weight Requires recalibration Units kg lb wrong selection See...

Страница 31: ...press input the cor respon ding A D count 11 Troubleshooting Guides 12 Technical Specifications 1 PROBLEM Defective battery Defective button s Power button not properly pressed Digits flash indicator Display does not respond to load changes Low battery Faulty load cell Display weight shows large error Scale is not Zeroed before applying weight Requires recalibration Units kg lb wrong selection See...

Страница 32: ... t g oz klb N kN are user selectable units Measurements units can be enabled independently and switched The default unit can be selected ABS IP65 RS 232C optional RS 232C optional Functions 21 set points calibration Zero scale Tare Low battery warning Peak hold Power down storage Power saving Date can be saved after power off Date can also be saved after removing batteries If inactive for a period...

Страница 33: ... t g oz klb N kN are user selectable units Measurements units can be enabled independently and switched The default unit can be selected ABS IP65 RS 232C optional RS 232C optional Functions 21 set points calibration Zero scale Tare Low battery warning Peak hold Power down storage Power saving Date can be saved after power off Date can also be saved after removing batteries If inactive for a period...

Страница 34: ...es 9 7979 Korea Seoul 9 7994 New York 9 8024 Kuwait Kuwait 9 7919 Philadelphia 9 8024 Lebanon Beirut 9 7964 San Francisco 9 7994 Mauritius Port Louis 9 7859 Venezuela Caracas 9 7829 33 ANYLOAD 805HP Handheld Digital Weighing Indicator User s Manual V1710 ANYLOAD 805HP Handheld Digital Weighing Indicator User s Manual V1710 34 13 Appendices 13 1 Seven segment digital display alphanumeric table 13 2...

Страница 35: ...es 9 7979 Korea Seoul 9 7994 New York 9 8024 Kuwait Kuwait 9 7919 Philadelphia 9 8024 Lebanon Beirut 9 7964 San Francisco 9 7994 Mauritius Port Louis 9 7859 Venezuela Caracas 9 7829 33 ANYLOAD 805HP Handheld Digital Weighing Indicator User s Manual V1710 ANYLOAD 805HP Handheld Digital Weighing Indicator User s Manual V1710 34 13 Appendices 13 1 Seven segment digital display alphanumeric table 13 2...

Страница 36: ...ww anyload com Email info anyload com Fax 1 866 612 9088 North America Toll Free 1 855 ANYLOAD 269 5623 805HP Handheld Digital Weight Indicator User s Manual V1710 Anyload Transducer Co Ltd Website www anyload com Email info anyload com ...

Отзывы: