User Manual
21
3) [FP + Card identify]: This mode means need swiping card after FP identified;
4) [FP + Success]: This mode means need directly pass after FP identified;
[Card verify first +]: The response of the device when the user first time use card
comparison on the device.
There are five modes:
1) [Card + No response]: This mode means the machine without response after
swiping card;
2) [Card + Password identify]: This mode means need input password after swiping
card;
3) [Card + FP identify (1:1)]: This mode means need press user finger after swiping
card;
4) [Card + FP + PWD identify]: This mode means need press user finger and input
password after swiping card;
5) [Card + Success]: This mode means directly pass after swiping card;
[PIN verify first +]: The response of the device when the user first time use ID
comparison on the device.
There are five modes:
1) [PIN + No response]: This mode means the machine without response after input
PIN;
2) [PIN + Password identify]: This mode means need input password after input PIN;
3) [PIN + FP identify (1:1)]: This mode means need press user finger after input PIN;
4) [PIN + FP +PWD identify]: This mode means need press user finger and input
password after input PIN;
5) [PIN + Success]: This mode means directly pass after input PIN;
After setting press [ESC] key to save and return to the previous menu.
Note:
If the identification
method doesn‘t math with the [Add user] in the [way of
comparison] settings, places [Add user] set subject than on the way; If [Add user] than
on the way in the system default, places the subject authentication.
2.3.6.4
Access
Access key to the lock control setup delay, wiegand mode and fix wiegand setting.
In [Main
Advanced] menu, press [
] key to select [Access] option and press [OK] key to
enter [Advanced
Access] interface:
[Relay control mode]: There are 5 modes.
1-Ring 2-Door open
means relay 1 control ring. Relay 2control lock
1- Door open
means only relay 1 control lock. Relay 2 disable
2- Door open
means only relay 2 control lock. Relay 1 disable
Содержание OA1000 Mercury
Страница 1: ... 2001 2013 Anviz Global Inc OA1000 User Manual V1 4 ...
Страница 65: ...User Manual 58 Click the item Remove from the Quick Access Toolbar ...
Страница 94: ...User Manual 87 Chapter6 FAQ Frequently asked questions and answers ...
Страница 98: ...User Manual 91 7 Appendix 7 1 Communication And Power Interface 7 2 Access Wiring Diagram 1 Connecting E Lock ...
Страница 100: ...User Manual 93 5 Wiegand Card Reader Connection 6 RS 485 Interface 7 RS 232 Interface ...
Страница 101: ...User Manual 94 ...