VERTICAL CONTACT TOASTER
14
P/N 1011373 Rev. C 03/18
McDonald’s
TROUBLESHOOTING (CONTINUED)
Problem
Possible Cause
Corrective Action
Toaster making unusual
sounds
Fan needs to be cleaned or replaced.
Clean fan as described in the Maintenance section of this manual
or contact Antunes Technical Service for assistance.
Conveyor belt chains have stretched or
adjusted incorrectly.
Adjust the conveyor belt chains as described in the Maintenance
section of this manual.
Motor Drive chain needs lubrication.
Lubricate chain.
Conveyor shaft bearing is binding.
Contact Antunes Technical Service for assistance.
Buns getting caught in bun
chute area
Bun chute installed incorrectly
Reinstall Bun chute correctly.
Toaster displays ERR 10.
Internal temperature of control compartment
exceeded 160° F.
Verify fan intake on back of toaster is clean, not blocked and has
proper spacing. Clean cooling fan if needed, if not rotting, contact
Antunes Technical Service. Check if cooling fan is functioning. If
not, replace fan..