P/N 1011582 Rev. F 07/21
13
Error Messages
If the steamer displays any error messages, turn the steamer
off and restart it. If the error persists, contact Antunes Technical
Service at 1-877-392-7854 (toll free).
WARNING
Before replacing any parts, or opening any side or rear panel from the steamer,
disconnect the steamers from the electrical power supply.
CAUTION
Use of any replacement part other than those supplied by Antunes of their authorized
distributors can cause injury to the operator and damage to the equipment and will
void all warranties.
Error
Description
FRAM Missing
Control Board Failure
Zero Cross
TC0 Open
Thermocouple Broken or Disconnected
TC1 Open
FlipFlop ON
Power Switch Circuit Malfunction
FlipFlop OFF
Bootload Fail
Software Update via USB Stick Failed
OPTION Write Failed
EEPROM Failure
MENU Write Failed
PID Write Failer
24V Missing
24VDC Power Supply Failed
Display Missing
Touch Screen Display Failed
Boiler Hot
Boiler Failed to Cool Down
Boiler Not Empty
Boiler Failed to Drain
Drain Timeout
Clean Drain Timeout
Boiler Failed to Cool Down
Initial Fill Timeout
Boiler Initial Water Fill Failed
Clean Fill Timeout
Boiler Clean Cycle Water Fill Failed
Refill Timeout
Boiler Normal Operation Water Fill Failed
Содержание IS-8000